W DOC AIRBUS | AMM A320F

Removal of the Ground Jack from the Air Intake Cowl


TASK 23-44-41-000-005-A
Removal of the Ground Jack from the Air Intake Cowl


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 210
ZONE: 410
ZONE: 420
ZONE: 430
ZONE: 440
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
430
ENG 1 AIR INTAKE, FAN AND ACCESS GEARBOX
440
ENG 2 AIR INTAKE, FAN AND ACCESS GEARBOX
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 23-44-41-860-062-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the panel 115VU:
  • Put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
   (2) Make sure that the engine 1(2) has been shutdown for at least 5 minutes.
   (3) On the panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Install a WARNING NOTICE(S).
4. Procedure
Subtask 23-44-41-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the ground jack
F Air Intake Cowl Interphone Jack ** ON A/C NOT FOR ALL
   (1) Remove the screws (11) which attach the cover (9) to the air intake cowl. Pull the cover and attached interphone jack assembly from the air intake cowl.
   (2) Remove the nut (18) and the washers (19) that attach the ground jack (21) to the air intake cowl structure.
   (3) Remove the ground wire (20) from the ground jack (21) .
   (4) Remove the ground jack (21) from air intake cowl.
   (5) Put a protective cover on the ground jack (21) and an insulation on the ground wire (20).
[Rev.10 from 2021] 2026.04.02 06:12:13 UTC