Removal of the Media Server
TASK 23-36-62-000-001-A
Removal of the Media Server
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-36-62-865-050-A ** ON A/C NOT FOR ALL
Subtask 23-36-62-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:11 UTC
Removal of the Media Server
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 23-36-62-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 23-36-62-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PES-VIDEO-CONTROL-VCC-DS/C | 21MH | C02 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 23-36-62-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Media Server
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the media server (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the media server (5) from its rack (2).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the media server (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the media server (5) from its rack (2).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
Illustration of the media server