W DOC AIRBUS | AMM A320F

Deactivation of the Wireless Access Point (WAP)


TASK 23-36-00-040-804-A
Deactivation of the Wireless Access Point (WAP)


ZONE: 210
ZONE: 220
FIN: 3010MH1 ** ON A/C NOT FOR ALL
FIN: 3010MH2 ** ON A/C NOT FOR ALL
FIN: 3010MH3 ** ON A/C NOT FOR ALL
FIN: 3010MH4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
220
FWD CAB UTILITY AREAS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 23-36-00-860-116-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 23-36-00-040-053-A ** ON A/C NOT FOR ALL
A. Deactivation of the Wireless Access Point (WAP)
   (1) Open, safety and tag the related circuit breaker(s) to do the deactivation procedure.
Subtask 23-36-00-865-149-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWAP27MHD07
5. Close-up
Subtask 23-36-00-860-117-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make an entry in the logbook.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:12:09 UTC