Removal of the Digital Interface Unit (DIU)
TASK 23-34-34-000-001-A
Removal of the Digital Interface Unit (DIU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-34-34-865-056-A ** ON A/C NOT FOR ALL
Subtask 23-34-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:08 UTC
Removal of the Digital Interface Unit (DIU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 23-34-34-865-056-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 23-34-34-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PES PFIS | 189MH | C07 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824.
Subtask 23-34-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Digital Interface Unit
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the Digital Interface Unit (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the Digital Interface Unit (5).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the Digital Interface Unit (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the Digital Interface Unit (5).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
Digital Interface Unit