Removal of the Passenger Entertainment System (PES) Main Multiplexer
TASK 23-33-31-000-001-A
Removal of the Passenger Entertainment System (PES) Main Multiplexer
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-33-31-010-050-A ** ON A/C NOT FOR ALL
Subtask 23-33-31-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:07 UTC
Removal of the Passenger Entertainment System (PES) Main Multiplexer
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 23-33-31-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door (Ref. AMM TASK 52-41-00-010-002) 824.
Subtask 23-33-31-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door (Ref. AMM TASK 52-41-00-010-002) 824.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 123VU | SHED BUS/218XP/220XP SPLY | 28XN | AC02 |
| 123VU | BUS 2/210XP/SPLY | 7XN2 | AF02 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PES-MUSIC - CTL | 21MK | D01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PES-MUSIC-CTL | 21MK | D01 |
Subtask 23-33-31-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Main Multiplexer PES
(1) Loosen the nut (3).
(2) Lower the nut (3).
(3) Pull the multiplexer (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the multiplexer (5) from its rack (2).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
(1) Loosen the nut (3).
(2) Lower the nut (3).
(3) Pull the multiplexer (5) on its rack (2) to disconnect the electrical connectors (1).
(4) Remove the multiplexer (5) from its rack (2).
(5) Put CAP - BLANKING on the disconnected electrical connectors (1).
PES Main Multiplexer