Initialization of the Prerecorded Announcement and Boarding Music (PRAM) Reproducer
TASK 23-32-00-860-002-A
Initialization of the Prerecorded Announcement and Boarding Music (PRAM) Reproducer
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-32-00-861-051-A ** ON A/C NOT FOR ALL Subtask 23-32-00-865-075-A ** ON A/C NOT FOR ALL
Subtask 23-32-00-860-053-D ** ON A/C NOT FOR ALL
Subtask 23-32-00-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:04 UTC
Initialization of the Prerecorded Announcement and Boarding Music (PRAM) Reproducer
FIN: 10RX ** ON A/C NOT FOR ALL
1. Reason for the Job- To Set the Audio Cassette(s) to the Starting Position
- To Inform the PRAM Reproducer about the Contents of the Audio Cassette(s)
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-32-00-700-001-A | Test of the Prerecorded Announcement Operation of the Prerecorded Announcement and Boarding Music (PRAM) Reproducer |
| TASK 23-32-00-860-001-A | Replacement of the Sound Recording Medium of the Prerecorded Announcement and Boarding Music (PRAM) Reproducer |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 23-32-00-861-051-A ** ON A/C NOT FOR ALL Subtask 23-32-00-865-075-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-32-00-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PRAM | 2RX | E01 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 128.
(2) Open the access door 824.
Subtask 23-32-00-820-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 128.
(2) Open the access door 824.
D. Preparation for Initialization
(1) Make sure that in the avionics compartment the audio cassette(s) is(are) installed correctly in the PRAM reproducer (10RX). (Ref. AMM TASK 23-32-00-860-001)
4. Procedure(1) Make sure that in the avionics compartment the audio cassette(s) is(are) installed correctly in the PRAM reproducer (10RX). (Ref. AMM TASK 23-32-00-860-001)
Subtask 23-32-00-860-053-D ** ON A/C NOT FOR ALL
A. Initialization of the PRAM Reproducer
(1) Open the C/B PRAM (2RX) on the C/B panel 2000VU.
(2) Close the C/B PRAM (2RX) on C/B panel 2000VU to reset the PRAM reproducer 10RX.
(3) Make sure that on the audio module of the FAP the ON ANNOUNCE display on the audio module of the FAP shows 'INI' to indicate that the initialization is in progress.
(4) Wait for up to 6 minutes.
(5) Make sure that after the initialization is completed:
Subtask 23-32-00-720-051-A ** ON A/C NOT FOR ALL (1) Open the C/B PRAM (2RX) on the C/B panel 2000VU.
(2) Close the C/B PRAM (2RX) on C/B panel 2000VU to reset the PRAM reproducer 10RX.
(3) Make sure that on the audio module of the FAP the ON ANNOUNCE display on the audio module of the FAP shows 'INI' to indicate that the initialization is in progress.
(4) Wait for up to 6 minutes.
(5) Make sure that after the initialization is completed:
- the cursor on the audio module of the FAP 120RH is in the MEMO 1 position
- the 'I-I' indication on the ON ANNOUNCE display goes off and a number is shown in its place.
B. Do the test of the prerecorded announcement operation of the PRAM reproducer (Ref. AMM TASK 23-32-00-700-001).
5. Close-upSubtask 23-32-00-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Subtask 23-32-00-862-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).