W DOC AIRBUS | AMM A320F

Installation of the Low Earth Orbit (LEO) Satellite Data Unit (SDU)


TASK 23-28-34-400-802-A
Installation of the Low Earth Orbit (LEO) Satellite Data Unit (SDU)


FIN: 1005RV1 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-28-00-600-802-A
Uploading of the SATCOM Software with a Laptop with Web Browser
TASK 23-28-00-740-001-A
BITE Test of the SATCOM system
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 46-21-00-710-005-A
SATCOM Link Test of the ATSU
3. Job Set-up
Subtask 23-28-34-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position below access door 824.
   (3) Make sure that access door 824 is open.
Subtask 23-28-34-865-071-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUSATCOM240RVK01
4. Procedure
Subtask 23-28-34-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the LEO SDU
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Install the SDU (1) on its rack (3).
   (6) Push the SDU (1) on its rack (3) and connect the electrical connectors (2).
   (7) Engage the nut (4) on the lug (5) and tighten it.
Subtask 23-28-34-865-072-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUSATCOM240RVK01
Subtask 23-28-34-610-052-A ** ON A/C NOT FOR ALL
C. Upload the SATCOM software component (Ref. AMM TASK 23-28-00-600-802).
Subtask 23-28-34-740-053-A ** ON A/C NOT FOR ALL
D. BITE Test of the SATCOM Status with the Multipurpose Control & Display Unit (MCDU)
   (1) Do the BITE test of the SATCOM system (Ref. AMM TASK 23-28-00-740-001).
Subtask 23-28-34-440-050-A ** ON A/C NOT FOR ALL
E. Activation of the Data Modulator-Demodulator (Modem) International Mobile-Equipment Identifier, if necessary.
   (1) On the MCDU, get access to the "SATCOM CONFIG" page.
ACTION
RESULT
1.On the MCDU main menu:
  • Push the line select key adjacent to the "SAT" indication.
On the MCDU:
  • The "SATCOM MAIN MENU" page comes into view.
  • Push the line select key adjacent to the "SATCOM STATUS" indication.
  • The "SATCOM STATUS" page comes into view.
  • Push the line select key adjacent to the "CONFIG" indication.
  • The "SATCOM CONFIG" page comes into view.
   (2) Do a check of the data-Modem international mobile-equipment identifier.
   (3) To operate the data-Modem international mobile-equipment identifier of the SDU, speak to the service provider.
NOTE: When the customer's service provider records the data-Modem international mobile-equipment-identifier of the SDU, it authenticates it on the iridium network and can then send Aircraft Communication Addressing and Reporting System (ACARS) messages.
Subtask 23-28-34-740-054-A ** ON A/C NOT FOR ALL
F. SATCOM Link Test of the Air Traffic Service Unit (ATSU)
   (1) If the SATCOM is correctly installed and the service provider operated it, do the SATCOM link test of the ATSU (Ref. AMM TASK 46-21-00-710-005).
5. Close-up
Subtask 23-28-34-410-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access door 824.
   (3) Remove the access platform(s).
Subtask 23-28-34-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).