Installation of the Satellite Data Unit (SDU)
TASK 23-28-34-400-001-A
Installation of the Satellite Data Unit (SDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-28-34-860-050-A ** ON A/C NOT FOR ALL
Subtask 23-28-34-420-050-A ** ON A/C NOT FOR ALL
Subtask 23-28-34-410-050-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.02 06:12:03 UTC
Installation of the Satellite Data Unit (SDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-28-00-600-002-A | Uploading of the USER ORT Part of the SATCOM Software |
| TASK 23-28-00-740-001-A | BITE Test of the Satellite Communication System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 23-28-34-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824.
(3) Make sure that the access door 824 is open.
Subtask 23-28-34-865-063-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824.
(3) Make sure that the access door 824 is open.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | SATCOM | 102RV1 | K01 |
Subtask 23-28-34-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the SDU
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the SDU (1) on its rack (3).
(6) Push the SDU (1) on its rack (3) to connect the electrical connector (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
Subtask 23-28-34-865-069-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the SDU (1) on its rack (3).
(6) Push the SDU (1) on its rack (3) to connect the electrical connector (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 23-28-34-610-050-D ** ON A/C NOT FOR ALL Subtask 23-28-34-740-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | SATCOM | 102RV1 | K01 |
Subtask 23-28-34-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Satellite Data Unit