W DOC AIRBUS | AMM A320F

Removal of the Satellite Data Unit (SDU)


TASK 23-28-34-000-001-A
Removal of the Satellite Data Unit (SDU)


ZONE: 128
FIN: 105RV1 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
128
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 23-28-34-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-28-34-010-050-A ** ON A/C NOT FOR ALL
B. Get access to the avionics compartment.
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
   (2) Open the access door 824.
Subtask 23-28-34-865-067-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUSATCOM102RV1K01
4. Procedure
Subtask 23-28-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the SDU
   (1) Loosen and lower the nuts (4).
   (2) Pull the SDU (1) on its rack (3) to disconnect the electrical connector (2).
   (3) Remove the SDU (1) from its rack (3).
   (4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.9 from 2019] 2026.04.02 06:12:03 UTC