Removal of the Satellite Data Unit (SDU)
TASK 23-28-34-000-001-A
Removal of the Satellite Data Unit (SDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-28-34-861-050-A ** ON A/C NOT FOR ALL Subtask 23-28-34-010-050-A ** ON A/C NOT FOR ALL
Subtask 23-28-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.02 06:12:03 UTC
Removal of the Satellite Data Unit (SDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 23-28-34-861-050-A ** ON A/C NOT FOR ALL Subtask 23-28-34-010-050-A ** ON A/C NOT FOR ALL
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 23-28-34-865-067-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | SATCOM | 102RV1 | K01 |
Subtask 23-28-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the SDU
(1) Loosen and lower the nuts (4).
(2) Pull the SDU (1) on its rack (3) to disconnect the electrical connector (2).
(3) Remove the SDU (1) from its rack (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Loosen and lower the nuts (4).
(2) Pull the SDU (1) on its rack (3) to disconnect the electrical connector (2).
(3) Remove the SDU (1) from its rack (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Satellite Data Unit