Removal of the SDU Configuration Module (SCM)
TASK 23-28-32-000-802-A
Removal of the SDU Configuration Module (SCM)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-28-32-861-050-A ** ON A/C NOT FOR ALL Subtask 23-28-32-010-051-A ** ON A/C NOT FOR ALL
Subtask 23-28-32-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:03 UTC
Removal of the SDU Configuration Module (SCM)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-28-32-000-803-A | Removal of the SIM Card from the SDU Configuration Module (SCM) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 23-28-32-861-050-A ** ON A/C NOT FOR ALL Subtask 23-28-32-010-051-A ** ON A/C NOT FOR ALL
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 23-28-32-865-056-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | SATCOM | 240RV | K01 |
Subtask 23-28-32-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the SDU Configuration Module (SCM)
(1) Remove the SIM card from the SCM and retain it if necessary (Ref. AMM TASK 23-28-32-000-803).
(2) Disconnect the connector (4).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the screws (2) and the washers (1).
(5) Remove the SCM (3).
(1) Remove the SIM card from the SCM and retain it if necessary (Ref. AMM TASK 23-28-32-000-803).
(2) Disconnect the connector (4).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the screws (2) and the washers (1).
(5) Remove the SCM (3).