BITE Test of the Multiple VHF Data Radio (MVDR) System
TASK 23-12-00-740-802-A
BITE Test of the Multiple VHF Data Radio (MVDR) System
To make sure that the VHF system operates correctly.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 23-12-00-860-053-A ** ON A/C NOT FOR ALL
Subtask 23-12-00-862-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:50:04 UTC
BITE Test of the Multiple VHF Data Radio (MVDR) System
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the JobTo make sure that the VHF system operates correctly.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-003-A | Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page |
Subtask 23-12-00-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On all RMPs, set the ON/OFF selector switch to ON.
(3) On the Multipurpose Control & Display Unit (MCDU), get access to the "SYSTEM REPORT/TEST/COM" page (Ref. AMM TASK 31-32-00-860-003).
Subtask 23-12-00-865-052-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On all RMPs, set the ON/OFF selector switch to ON.
(3) On the Multipurpose Control & Display Unit (MCDU), get access to the "SYSTEM REPORT/TEST/COM" page (Ref. AMM TASK 31-32-00-860-003).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/RMP/1 | 2RG1 | G10 |
| 49VU | COM/VHF/1 | 2RC1 | G09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RMP/3 | 2RG3 | L03 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/VHF/3 | 2RC3 | L05 |
| 121VU | COM NAV/VHF/2 | 2RC2 | L04 |
| 121VU | COM NAV/RMP/2 | 2RG2 | L02 |
NOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
Subtask 23-12-00-740-051-A ** ON A/C NOT FOR ALL A. BITE Test of the MVDR System
5. Close-up| ACTION | RESULT |
|---|---|
1.On the MCDU, on the COM menu page:
| On the MCDU:
|
2.On the MCDU, on the VHF-1 (2, 3) page:
| On the MCDU:
|
3.On the MCDU:
| On the MCDU:
|
Subtask 23-12-00-862-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On all RMPs, set the ON/OFF selector switch to OFF.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) On all RMPs, set the ON/OFF selector switch to OFF.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).