W DOC AIRBUS | AMM A320F

Deactivation of the VHF System


TASK 23-12-00-040-801-A
Deactivation of the VHF System


1. Reason for the Job
MMEL 23-12-01
VHF COMMUNICATION SYSTEMS (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 23-12-00-861-055-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-12-00-865-060-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/VHF/12RC1G09
** ON A/C NOT FOR ALL
121VUCOM NAV/VHF/32RC3L05
121VUCOM NAV/VHF/22RC2L04
** ON A/C NOT FOR ALL
121VUCOM/VHF/32RC3L05
121VUCOM/VHF/22RC2L04
4. Procedure
Subtask 23-12-00-040-050-A
A. Deactivation of the VHF System
   (1) For the deactivation of the VHF1 system:
     (a) Open, safety and tag this(these) circuit breaker(s):
  • 2RC1.
   (2) For the deactivation of the VHF2 system:
     (a) Open, safety and tag this(these) circuit breaker(s):
  • 2RC2.
   (3) For the deactivation of the VHF3 system:
     (a) Open, safety and tag this(these) circuit breaker(s):
  • 2RC3.
5. Close-up
Subtask 23-12-00-860-068-A
A. Aircraft Maintenance Configuration
   (1) Make an entry in the logbook.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (3) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.02 06:11:59 UTC