W DOC AIRBUS | AMM A320F

BITE Test of the High Frequency (HF) System


TASK 23-11-00-740-001-A
BITE Test of the High Frequency (HF) System


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
To make sure that the HF system operates correctly.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-003-A
Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page
3. Job Set-up
Subtask 23-11-00-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the annunciator lights on the front panel of the transceivers do not come on.
   (3) On all RMPs, set the ON/OFF selector switch to ON.
   (4) On one Multipurpose Control & Display Unit (MCDU), get access to the "SYSTEM REPORT/TEST COM" page (Ref. AMM TASK 31-32-00-860-003).
Subtask 23-11-00-860-054-F ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the annunciator lights on the front panel of the transceivers do not come on.
   (3) On all RMPs, set the ON/OFF selector switch to ON.
   (4) On one Multipurpose Control & Display Unit (MCDU), get access to the "SYSTEM REPORT/TEST COM" page (Ref. AMM TASK 31-32-00-860-003).
Subtask 23-11-00-865-068-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/RMP/12RG1G10
** ON A/C NOT FOR ALL
49VUHF11RE1HA14
** ON A/C ALL
121VUCOM NAV/RMP/22RG2L02
** ON A/C NOT FOR ALL
121VUCOM NAV/RMP/32RG3L03
** ON A/C NOT FOR ALL
121VUCOM NAV/HF21RE2L13
Subtask 23-11-00-875-051-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/RMP/12RG1G10
** ON A/C NOT FOR ALL
49VUHF11RE1HA14
** ON A/C ALL
121VUCOM NAV/RMP/22RG2L02
** ON A/C NOT FOR ALL
121VUCOM NAV/RMP/32RG3L03
** ON A/C NOT FOR ALL
121VUCOM NAV/HF21RE2L13
4. Procedure
Subtask 23-11-00-740-050-A ** ON A/C NOT FOR ALL
A. BITE Test of the HF System
ACTION
RESULT
1.On the MCDU, on the COM menu page:
  • Push the line key adjacent to the HF1 indication.
On the MCDU:
  • The HF-1 page comes into view.
2.On the HF-1 page:

  • Push the line key adjacent to the TEST indication.
  • The HF-1 TEST page comes into view.
3.On the HF-1 TEST page:
  • Push the line selection key adjacent to the START TEST.
On the HF-1 TEST page:
  • TEST IN PROGRESS indication comes into view.
  • TEST OK indication comes into view.
4.On the MCDU keyboard:
  • Push the MCDU MENU mode key.
  • The MCDU MENU page comes into view.
Subtask 23-11-00-740-050-E ** ON A/C NOT FOR ALL
A. BITE Test of the HF System
NOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
ACTION
RESULT
1.On the MCDU, on the COM menu page:
  • Push the line key adjacent to the HF1(HF2) indication.
On the MCDU:
  • The HF-1(2) page comes into view.
2.On the HF-1(2) page:

  • Push the line key adjacent to the TEST indication.
  • The HF-1(2) TEST page comes into view.
3.On the HF-1(2) TEST page:
  • Push the line selection key adjacent to the START TEST.
On the HF-1(2) TEST page:
  • TEST IN PROGRESS indication comes into view.
  • TEST OK indication comes into view.
4.On the MCDU keyboard:
  • Push the MCDU MENU mode key.
  • The MCDU MENU page comes into view.
5. Close-up
Subtask 23-11-00-862-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) On all RMPs, set the ON/OFF selector switch to OFF.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:49:53 UTC