W DOC AIRBUS | AMM A320F

Uploading of the High Frequency Data Radio (HFDR) Software


TASK 23-11-00-600-801-A
Uploading of the High Frequency Data Radio (HFDR) Software


NOTE: If HFDR 2 is installed, it is necessary to do the uploading for each HFDR transceiver in the sequence that follows:
- Upload the software to HFDR transceiver 1.
- Interchange the two HFDR transceivers.
- Upload the software to the other HFDR transceiver.
- Put the HFDR transceivers back to their initial positions.
ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 31-32-00-860-003-A
Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page
TASK 31-38-00-610-804-A
Onboard Software Uploading Procedure
3. Job Set-up
Subtask 23-11-00-861-053-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-11-00-860-067-A ** ON A/C NOT FOR ALL
B. Prepare the media disk(s).
   (1) Get the media disk(s) from the storage box in the cockpit.
   (2) Make sure that the Part Number(s) (P/N) written on the media disk(s) is(are) the same as the P/N written in the airline configuration-management document.
     (a) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
Subtask 23-11-00-865-066-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1B01
** ON A/C NOT FOR ALL
49VUHF11RE1HA14
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1H07
** ON A/C NOT FOR ALL
121VUDATA/LOADER/SPLY3TDJ16
121VUDLSU &/DLRB/SPLY5TDJ15
121VUPDL/PWR/SPLY14TDK19
** ON A/C NOT FOR ALL
121VUAUTO FLT/MCDU/211CA2N20
** ON A/C NOT FOR ALL
121VUPDL/PWR/SPLY14TDJ45
121VUDATA/LOADER/SPLY3TDJ39
121VUDLSU &/DLRB/SPLY5TDJ38
Subtask 23-11-00-860-070-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
Action
Result
1.On the ECAM control panel:
  • Push the BLEED key to get the BLEED page.
On the lower ECAM DU:
  • The BLEED page comes into view.
  • The white GND indication comes into view in the middle area of the page.
Subtask 23-11-00-280-050-A ** ON A/C NOT FOR ALL
E. Do a Check of the Reference(s) of the Software Pre-loaded in the HFDR Transceiver
   (1) Get access to the SYSTEM REPORT/TEST/COM page (Ref. AMM TASK 31-32-00-860-003).
   (2) If the access to the HF 1 menu page and then to the LRU IDENTIFICATION page is not possible:
  • No software is loaded in the HFDR transceiver and you can do the uploading procedure as given in Para 4.A.
   (3) If the access to the LRU IDENTIFICATION page is possible:
  • Do a check of the reference of the software pre-loaded in the HFDR transceiver:
ACTION
RESULT
1.On the MCDU, on the SYSTEM REPORT/TEST/COM page:
  • Push the line key adjacent to the HF 1 indication.
On the MCDU:
  • The HF 1 menu page comes into view.
2.On the HF 1 page:
  • Push the line key adjacent to the LRU IDENT indication.
On the MCDU:
  • The LRU IDENTIFICATION page comes into view.
   (4) Make sure that the reference of the software pre-loaded in the HFDR transceiver on the LRU IDENTIFICATION page is different from the reference of the software written on the media disk(s).
4. Procedure
Subtask 23-11-00-610-050-A ** ON A/C NOT FOR ALL
A. Upload the HFDR 1 Software (with the PDL through ARINC 615)
   (1) Do the onboard software-uploading procedure (Ref. AMM TASK 31-38-00-610-804).
Subtask 23-11-00-280-051-A ** ON A/C NOT FOR ALL
B. Do a Check of the Reference(s) of the Software Loaded in the HFDR Transceiver
   (1) Get access to the SYSTEM REPORT/TEST/COM page (Ref. AMM TASK 31-32-00-860-003).
   (2) Do a check of the reference of the software loaded in the HFDR 1 transceiver:
ACTION
RESULT
1.On the MCDU, on the SYSTEM REPORT/TEST/COM page:
  • Push the line key adjacent to the HF 1 indication.
On the MCDU:
  • The HF 1 menu page comes into view.
2.On the HF 1 page:
  • Push the line key adjacent to the LRU IDENT indication.
On the MCDU:
  • The LRU IDENTIFICATION page comes into view.
   (3) Make sure that the reference of the software loaded in the HFDR 1 transceiver on the LRU IDENTIFICATION page is the same as the reference of the software written on the media disk(s).
5. Close-up
Subtask 23-11-00-860-069-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.
   (2) On the MCDU, fully decrease the intensity of the light of the MCDU screen (display off).
   (3) Put the media disk(s) back into the storage box in the cockpit.
Subtask 23-11-00-862-055-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:11:56 UTC