W DOC AIRBUS | AMM A320F

Removal of the Multipurpose Control & Display Unit (MCDU)


TASK 22-82-12-000-001-A
Removal of the Multipurpose Control & Display Unit (MCDU)


ZONE: 210
FIN: 3CA1
FIN: 3CA2
FIN: 3CA3 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
F MCDU ** ON A/C NOT FOR ALL
F MCDU ** ON A/C NOT FOR ALL
F MCDU ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 22-82-12-860-052-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 22-82-12-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/INSTL LT/MAIN INST/PNL AND/PED4LFY04
** ON A/C NOT FOR ALL
FOR FIN: 3CA1 (MCDU1)
49VUAUTO FLT/MCDU/111CA1B01
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1H07
** ON A/C ALL
FOR FIN: 3CA2 (MCDU2)
121VUAUTO FLT/MCDU/211CA2N20
4. Procedure
Subtask 22-82-12-020-051-A
A. Removal of the MCDU
NOTE: This procedure is applicable to each MCDU.
   (1) Loosen the Dzus fasteners (1).
   (2) Pull the MCDU (2) from its housing.
   (3) Before you disconnect the electrical connectors, make sure that there is identification on them. This is important for the subsequent installation procedure.
   (4) Disconnect the electrical connector(s) (4).
   (5) Remove the MCDU (2).
   (6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.