Removal of the FCU
TASK 22-81-12-000-001-A
Removal of the FCU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 22-81-12-865-050-A
Subtask 22-81-12-020-051-B
[Rev.10 from 2021]
2026.03.31 23:11:06 UTC
Removal of the FCU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 22-81-12-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/FCU/1 | 9CA1 | B05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/FCU/1 | 9CA1 | H11 |
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/FCU/2 | 9CA2 | M21 |
| 122VU | LIGHTING/INSTL LT/GLARE/SHLD | 5LF | Y05 |
Subtask 22-81-12-020-051-B
A. Removal of the FCU
(2) Open the lower panel (6).
(3) Remove the four screws (3) and washers (4) from the FCU (1).
(4) Pull the FCU (1) from its housing (8).
(5) Disconnect the electrical connectors (7).
(6) Remove the FCU (1).
(7) Put CAP - BLANKING on the electrical connectors (2) and (7).
NOTE: You will continue to see the displays for some time after you open the two FCU circuit breakers. You can ignore this (it is because of the residual polarization of the liquid crystals).
(1) Hold the lower panel (6) and loosen the three Dzus fasteners (5) by a quarter turn. (2) Open the lower panel (6).
(3) Remove the four screws (3) and washers (4) from the FCU (1).
(4) Pull the FCU (1) from its housing (8).
(5) Disconnect the electrical connectors (7).
(6) Remove the FCU (1).
(7) Put CAP - BLANKING on the electrical connectors (2) and (7).
FCU