W DOC AIRBUS | AMM A320F

Detailed Visual Inspection of the Cockpit (Cabin) Temperature Sensor and Ducting for Contamination


TASK 21-63-17-210-001-A
Detailed Visual Inspection of the Cockpit (Cabin) Temperature Sensor and Ducting for Contamination


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 210
ZONE: 230
ZONE: 240
ZONE: 250
FIN: 21HK
FIN: 22HK
FIN: 23HK
1. Reason for the Job
This task content with reference to the MPD Task 216000-01 moved to task 216317-210-001 in pageblock 21-63-00-07.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
BRUSH - BRISTLED, SOFT
No specific
1
VACUUM CLEANER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBB1)
Non Aqueous Cleaner-- Petroleum Based -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
230
FWD PASSENGER COMPARTMENT
240
MID PASSENGER COMPARTMENT
250
AFT PASSENGER COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 21-63-17-000-001-A
Removal of the Temperature Sensors
TASK 21-63-17-400-001-A
Installation of the Temperature Sensors
3. Job Set-up
Subtask 21-63-17-020-054-A
A. Remove the cockpit (cabin) temperature sensor (Ref. AMM TASK 21-63-17-000-001).
4. Procedure
Subtask 21-63-17-210-052-A
A. Visual Inspection of the Temperature Sensors
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
   (1) Make sure that the temperature sensors are clean and in the correct condition.
     (a) If necessary clean the sensors with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) (or equivalent) , a clean Textile-Lint free Cotton - (Material No.14SBA1) and a BRUSH - BRISTLED, SOFT.
   (2) Make sure that the temperature sensor housings, pipe casings, ducts and flexible hoses are free from contamination and in the correct condition.
     (a) If there is a layer of dust in a Cabin Temperature Sensor casing, the temperature sensor housings, pipe casings, ducts or flexible hoses, use a VACUUM CLEANER or an air blower to remove it.
NOTE: A high dust concentration can quickly cause sensor contamination.
   (3) Do a visual inspection of the area behind the ceiling panels for contamination.
5. Close-up
Subtask 21-63-17-420-053-A
A. Install the cockpit (cabin) temperature sensor (Ref. AMM TASK 21-63-17-400-001).
[Rev.10 from 2021] 2026.04.02 06:11:44 UTC