Cleaning of Cabin Sensor Duct and Temperature Sensor
TASK 21-63-00-100-801-A
Cleaning of Cabin Sensor Duct and Temperature Sensor
Refer to the MPD TASK: 216000-01
CLEANING OF CABIN SENSOR DUCT AND TEMPERATURE SENSOR.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 21-63-00-020-053-A 4. Procedure
Subtask 21-63-00-100-051-A
Subtask 21-63-00-420-050-A
[Rev.10 from 2021]
2026.04.02 06:11:43 UTC
Cleaning of Cabin Sensor Duct and Temperature Sensor
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 216000-01
CLEANING OF CABIN SENSOR DUCT AND TEMPERATURE SENSOR.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | BRUSH - BRISTLED, SOFT |
| No specific | 1 | VACUUM CLEANER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 230 | FWD PASSENGER COMPARTMENT |
| 240 | MID PASSENGER COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-63-17-000-001-A | Removal of the Temperature Sensors |
| TASK 21-63-17-400-001-A | Installation of the Temperature Sensors |
Subtask 21-63-00-020-053-A 4. Procedure
Subtask 21-63-00-100-051-A
A. Cleaning of the Temperature Sensors
(a) If necessary clean the sensors with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) (or equivalent) , a clean Textile-Lint free Cotton - (Material No.14SBA1) and a BRUSH - BRISTLED, SOFT.
(2) Make sure that the temperature sensor housings, pipe casings, ducts and flexible hoses are free from contamination and in the correct condition.
(a) If there is a layer of dust in a Cabin Temperature Sensor casing, the temperature sensor housings, pipe casings, ducts or flexible hoses, use a VACUUM CLEANER or an air blower to remove it.
5. Close-upWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Make sure that the temperature sensors are clean and in the correct condition. (a) If necessary clean the sensors with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) (or equivalent) , a clean Textile-Lint free Cotton - (Material No.14SBA1) and a BRUSH - BRISTLED, SOFT.
(2) Make sure that the temperature sensor housings, pipe casings, ducts and flexible hoses are free from contamination and in the correct condition.
(a) If there is a layer of dust in a Cabin Temperature Sensor casing, the temperature sensor housings, pipe casings, ducts or flexible hoses, use a VACUUM CLEANER or an air blower to remove it.
NOTE: A high dust concentration can quickly cause sensor contamination.
(3) Do a visual inspection of the area behind the ceiling panels for contamination. Subtask 21-63-00-420-050-A