Removal of the Anti-Ice Valve Sense-Lines Assembly
TASK 21-61-41-000-002-A
Removal of the Anti-Ice Valve Sense-Lines Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-61-41-861-051-A ** ON A/C NOT FOR ALL Subtask 21-61-41-865-063-A ** ON A/C NOT FOR ALL
Subtask 21-61-41-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:39 UTC
Removal of the Anti-Ice Valve Sense-Lines Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [10HM] (PACK 1-AIR CONDITIONING) | |
| 191BB, 191KB | |
| FOR [11HM] (PACK 2-AIR CONDITIONING) | |
| 192FB, 192KB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
Subtask 21-61-41-861-051-A ** ON A/C NOT FOR ALL Subtask 21-61-41-865-063-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-61-41-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM (PACK 1AIR CONDITIONING) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| FOR FIN: 11HM (PACK 2AIR CONDITIONING) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
C. Get Access
(1) Remove the access panel(s) (Ref. AMM TASK 53-35-13-000-002)
(a) FOR [10HM] (PACK 1-AIR CONDITIONING)
(b) FOR [11HM] (PACK 2-AIR CONDITIONING)
4. Procedure(1) Remove the access panel(s) (Ref. AMM TASK 53-35-13-000-002)
(a) FOR [10HM] (PACK 1-AIR CONDITIONING)
(b) FOR [11HM] (PACK 2-AIR CONDITIONING)
Subtask 21-61-41-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Sense Lines Assembly
(1) At the anti-ice valve (3) disconnect the sense line connectors (4), (5), (6) and (7).
(2) At the air cycle machine (1) disconnect the sense line connector (2).
(3) At the condensor (14) disconnect the sense line connectors (11), (12) and (13).
(4) Remove the sense lines assembly from the aircraft.
(5) Put the PLUG-BLANKING in each disconnected line end.
Subtask 21-61-41-020-053-B ** ON A/C NOT FOR ALL (1) At the anti-ice valve (3) disconnect the sense line connectors (4), (5), (6) and (7).
(2) At the air cycle machine (1) disconnect the sense line connector (2).
(3) At the condensor (14) disconnect the sense line connectors (11), (12) and (13).
(4) Remove the sense lines assembly from the aircraft.
(5) Put the PLUG-BLANKING in each disconnected line end.
A. Removal of the Sense Lines Assembly
(1) At the anti-ice valve (3) disconnect the sense line connectors (7), (8), (9) and (10).
(2) At the solenoid (5) disconnect the sense line connectors (4) and (6),
(3) At the air cycle machine (1) disconnect the sense line connector (2).
(4) At the condensor (14) disconnect the sense line connectors (11), (12) and (13).
(5) Remove the sense lines assembly from the aircraft.
(6) Put the PLUG-BLANKING in each disconnected line end.
(1) At the anti-ice valve (3) disconnect the sense line connectors (7), (8), (9) and (10).
(2) At the solenoid (5) disconnect the sense line connectors (4) and (6),
(3) At the air cycle machine (1) disconnect the sense line connector (2).
(4) At the condensor (14) disconnect the sense line connectors (11), (12) and (13).
(5) Remove the sense lines assembly from the aircraft.
(6) Put the PLUG-BLANKING in each disconnected line end.
Anti-Ice Valve Sense-Lines Assembly - Component Location