W DOC AIRBUS | AMM A320F

Removal of the Anti-Ice Valve


TASK 21-61-41-000-001-A
Removal of the Anti-Ice Valve


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for both the anti-ice valves 17HH and 37HH.
FIN: 17HH ** ON A/C NOT FOR ALL
FIN: 37HH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [17HH] (VALVE-ANTI ICE)
191KB
FOR [37HH] (VALVE-ANTI ICE)
192KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
F Anti-icing Valve. ** ON A/C NOT FOR ALL
F Anti-icing Valve. ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-61-41-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-61-41-865-060-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 17HH (VALVEANTI ICE)
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
FOR FIN: 37HH (VALVEANTI ICE)
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
Subtask 21-61-41-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Remove the access panel(s) (Ref. AMM TASK 53-35-13-000-002)
     (a) FOR [17HH] (VALVE-ANTI ICE)
     (b) FOR [37HH] (VALVE-ANTI ICE)
4. Procedure
Subtask 21-61-41-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Anti-ice Valve
   (1) Disconnect the electrical connector (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Disconnect the sense line connectors (4), (5), (14) and (18) and the pneumatic sense hose (9).
   (4) Put the PLUG-BLANKING in each disconnected line end.
   (5) Remove the nut (17), the washer (15), the screw (11) and disconnect the bonding strap (10).
   (6) Remove the clamps (6) and (12) and the anti-ice valve (13).
   (7) Remove the packings (2) and (7).
   (8) Put the PLUG-BLANKING in each disconnected line end.
Subtask 21-61-41-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Anti-ice Valve
   (1) Disconnect the electrical connector (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Disconnect the sense line connectors (4), (5), (12) and (14) and the pneumatic sense hose (16).
   (4) Put the PLUG-BLANKING in each disconnected line end.
   (5) Remove the nut (15), the washer (17), the screw (9) and disconnect the bonding strap (13).
   (6) Remove the clamps (6) and (10) and the anti-ice valve (11).
   (7) Remove the packings (2) and (7).
   (8) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 06:11:39 UTC