Removal of the Pack-Outlet Pneumatic Sensor
TASK 21-61-19-000-001-A
Removal of the Pack-Outlet Pneumatic Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-61-19-865-053-A ** ON A/C NOT FOR ALL
Subtask 21-61-19-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:38 UTC
Removal of the Pack-Outlet Pneumatic Sensor
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the pack-outlet pneumatic sensors 10HM10 and 11HM10.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC) | |
| 191BB | |
| FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC) | |
| 192FB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
Subtask 21-61-19-865-053-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-61-19-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 49VU | AIR COND/FLOW/CTL &/IND1 | 1HB | D07 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| FOR FIN: 11HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 122VU | AIR COND/FLOW/CTL AND IND/2 | 2HB | V21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
B. Get Access
(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB.
4. Procedure(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB.
Subtask 21-61-19-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pack-Outlet Pneumatic Sensor
(1) Disconnect the sense line (3).
(2) Put the PLUG-BLANKING in each disconnected line end.
(3) Remove and discard the lockwire.
(4) Remove the screws (1), the washers (2) and the pack-outlet pneumatic sensor (4).
(5) Remove the packing (5) from the pack-outlet pneumatic sensor (4).
(6) Put the PLUG-BLANKING in each disconnected line end.
(1) Disconnect the sense line (3).
(2) Put the PLUG-BLANKING in each disconnected line end.
(3) Remove and discard the lockwire.
(4) Remove the screws (1), the washers (2) and the pack-outlet pneumatic sensor (4).
(5) Remove the packing (5) from the pack-outlet pneumatic sensor (4).
(6) Put the PLUG-BLANKING in each disconnected line end.
Pack Outlet Pneumatic-Sensor