W DOC AIRBUS | AMM A320F

Removal of the Pack Outlet - Temperature Sensors


TASK 21-61-15-000-001-A
Removal of the Pack Outlet - Temperature Sensors


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for pack-outlet temperature sensor 13HH and 34HH.
FIN: 13HH
FIN: 34HH
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [13HH] (SENSOR-PACK OUTLET TEMP)
191BB
FOR [34HH] (SENSOR-PACK OUTLET TEMP)
192FB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
F Pack Outlet - Temperature Sensor ** ON A/C NOT FOR ALL
F Pack Outlet - Temperature Sensor ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-61-15-861-050-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-61-15-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 13HH (SENSORPACK OUTLET TEMP)
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
** ON A/C NOT FOR ALL
FOR FIN: 34HH (SENSORPACK OUTLET TEMP)
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 21-61-15-010-050-A
C. Get Access
   (1) Remove the access panel/s (Ref. AMM TASK 53-35-13-000-002).
     (a) FOR [13HH] (SENSOR-PACK OUTLET TEMP)
     (b) FOR [34HH] (SENSOR-PACK OUTLET TEMP)
4. Procedure
Subtask 21-61-15-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Pack Outlet-Temperature Sensor
   (1) Disconnect the electrical connector (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire.
   (4) Remove the pack outlet-temperature sensor (1).
   (5) Put the PLUG-BLANKING in each disconnected line end.
   (6) Remove and discard the packing (3) from the pack outlet-temperature sensor (1).
   (7) Put the PLUG-BLANKING in each disconnected line end.
Subtask 21-61-15-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Pack Outlet-Temperature Sensor
   (1) Disconnect the electrical connector (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire.
   (4) Remove the pack outlet-temperature sensor (1).
   (5) Put the PLUG-BLANKING in each disconnected line end.
   (6) Remove and discard the packings (3) and the washer (4) from the pack outlet-temperature sensor (1).
   (7) Put the PLUG-BLANKING in each disconnected line end.