Removal of the Pack Discharge Pressure Sensor
TASK 21-61-14-000-001-A
Removal of the Pack Discharge Pressure Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-61-14-861-050-A ** ON A/C NOT FOR ALL Subtask 21-61-14-865-050-A ** ON A/C NOT FOR ALL
Subtask 21-61-14-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:37 UTC
Removal of the Pack Discharge Pressure Sensor
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the pack discharge pressure sensors 14HH and 20HH.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [14HH] (P1 PACK DISCH PRESS SENSOR) | |
| 191KB | |
| FOR [20HH] (P2 PACK DISCH PRESS SENSOR) | |
| 192FB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
Subtask 21-61-14-861-050-A ** ON A/C NOT FOR ALL Subtask 21-61-14-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-61-14-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 14HH (P1 PACK DISCH PRESS SENSOR) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| FOR FIN: 20HH (P2 PACK DISCH PRESS SENSOR) | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
C. Get Access
(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002),
(a) FOR [14HH] (P1 PACK DISCH PRESS SENSOR)
191KB.
(b) FOR [20HH] (P2 PACK DISCH PRESS SENSOR)
192FB.
4. Procedure(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002),
(a) FOR [14HH] (P1 PACK DISCH PRESS SENSOR)
191KB.
(b) FOR [20HH] (P2 PACK DISCH PRESS SENSOR)
192FB.
Subtask 21-61-14-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pack Discharge Pressure Sensor
(1) Disconnect the electrical connector (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the pressure sense lines (9) and (10).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Remove the nut (2), the washer (3), the screw (4) and disconnect the bonding strap (5).
(6) Remove the screws (6) and the washers (7).
(7) Remove the pack discharge pressure sensor (11) and the clamps (8) at the same time.
(8) Remove the clamps (8) from the pack discharge pressure sensor (11).
(1) Disconnect the electrical connector (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the pressure sense lines (9) and (10).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Remove the nut (2), the washer (3), the screw (4) and disconnect the bonding strap (5).
(6) Remove the screws (6) and the washers (7).
(7) Remove the pack discharge pressure sensor (11) and the clamps (8) at the same time.
(8) Remove the clamps (8) from the pack discharge pressure sensor (11).
Pack Discharge Pressure Sensor