Operational Test of the Pack Temperature-Control System
TASK 21-61-00-710-001-A
Operational Test of the Pack Temperature-Control System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 21-61-00-861-059-A Subtask 21-61-00-865-075-A
Subtask 21-61-00-710-050-B ** ON A/C NOT FOR ALL
Subtask 21-61-00-860-050-A
[Rev.10 from 2021]
2026.04.02 06:11:37 UTC
Operational Test of the Pack Temperature-Control System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-002-A | Procedure to Get Access to the SYSTEM REPORT/TEST/AIR COND Page |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TSM 21-61-00-810-820 | Pack 1 Electrical Component with Short Circuit (AIR PACK 1 REGUL FAULT) |
| TSM 21-61-00-810-821 | Pack 2 Electrical Component with Short Circuit (AIR PACK 2 REGUL FAULT) |
| TSM 21-61-00-810-863 | Pack 1 Control - No Test Result |
| TSM 21-61-00-810-864 | Pack 2 Control - No Test Result |
| TSM 21-61-00-810-888 | MCDU - NO TEST Indications |
Subtask 21-61-00-861-059-A Subtask 21-61-00-865-075-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-61-00-860-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS2 | 4HK | V20 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS1 | 3HK | V19 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS2 | 2HK | V18 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS1 | 1HK | V17 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
C. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) Make sure that on the ECAM BLEED page both of the pack flow-control valve symbols show closed.
Subtask 21-61-00-860-051-B ** ON A/C NOT FOR ALL (1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) Make sure that on the ECAM BLEED page both of the pack flow-control valve symbols show closed.
NOTE: The test is only available if both pack flow-control symbols show closed on the BLEED page.
(3) On the AIR COND panel 30VU, make sure that: - the HOT AIR pushbutton switch is in the on position (the OFF and FAULT legends are off).
- the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).
C. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) Make sure that on the ECAM BLEED page both of the pack flow-control valve symbols show closed.
(5) On one MCDU get the SYSTEM REPORT/TEST AIR COND menu page (Ref. AMM TASK 31-32-00-860-002).
4. Procedure(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) Make sure that on the ECAM BLEED page both of the pack flow-control valve symbols show closed.
NOTE: The test is only available if both pack flow-control symbols show closed on the BLEED page.
(3) On the AIR COND panel 30VU, make sure that: - the HOT AIR pushbutton switch is in the on position (the OFF and FAULT legends are off).
- the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).
(5) On one MCDU get the SYSTEM REPORT/TEST AIR COND menu page (Ref. AMM TASK 31-32-00-860-002).
Subtask 21-61-00-710-050-B ** ON A/C NOT FOR ALL
A. Operational Test of the Pack Temperature-Control System
Subtask 21-61-00-710-050-C ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.On the AIR COND menu page: | On the MCDU: |
|
|
| 2.On the CAB TEMP CONT menu page: | |
|
|
| 3.On the CAB TEMP CONT TEST page: | |
|
|
NOTE: If the test shows:
NO TEST RESULT RECEPTION FROM P1/P2 CONT instead of TEST OK:
NO TEST RESULT RECEPTION FROM P1/P2 CONT instead of TEST OK:
- do the related trouble shooting procedure TSM 21-61-00-810-863 or TSM 21-61-00-810-864.
NO TEST RESULT RECEPTION FROM P1/P2 CONT instead of TEST OK and the post flight report gives the warning AIR PACK 1/2 REGUL FAULT: - do the related trouble shooting procedure TSM 21-61-00-810-820 or TSM 21-61-00-810-821.
A. Operational Test of the Pack Temperature-Control System
(1) Make sure that all bleed air sources (Engine, APU and/or HP ground supply) are disconnected or shut down.
5. Close-up(1) Make sure that all bleed air sources (Engine, APU and/or HP ground supply) are disconnected or shut down.
NOTE: The presence of bleed air pressure in the system could lead to test performance failure.
| ACTION | RESULT |
|---|---|
| 1.On the AIR COND menu page: | On the MCDU: |
|
|
| 2.On the CAB TEMP CONT menu page: | |
|
NOTE: If the test shows: NO TEST: PACK1 NOT OFF and PACK2 NOT OFF instead of TEST OK but the pack pushbutton switches are in the off position:
|
| 3.On the CAB TEMP CONT SYSTEM TEST page: | |
| |
| 4.On the CAB TEMP CONT SYSTEM TEST page: | |
|
|
Subtask 21-61-00-860-050-A
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).