Deactivation of the Air Inlet Flap in the Open Position
TASK 21-61-00-040-002-A
Deactivation of the Air Inlet Flap in the Open Position
MMEL 21-52-02A
AIR CONDITIONING PACK RAM AIR INLET FLAP
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-61-00-861-053-A Subtask 21-61-00-865-053-A
Subtask 21-61-00-040-050-A
Subtask 21-61-00-865-063-A
[Rev.10 from 2021]
2026.04.02 06:11:36 UTC
Deactivation of the Air Inlet Flap in the Open Position
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the Left and the Right air inlet flaps.
1. Reason for the JobMMEL 21-52-02A
AIR CONDITIONING PACK RAM AIR INLET FLAP
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | 1 | RULER - STEEL |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [28HH] (P2 RAM AIR IN ACTUATOR) | |
| 192KB | |
| FOR [8HH] (P1 RAM AIR IN ACTUATOR) | |
| 191KB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-61-51-000-001-A | Removal of the Air-Inlet Flap Actuator |
| TASK 21-61-51-820-001-A | Adjustment of the Air Inlet Flap |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
| TASK 53-35-13-400-002-A | Installation of the Quick-Release Access Panels on the Belly Fairing Structure |
Subtask 21-61-00-861-053-A Subtask 21-61-00-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-61-00-220-050-B | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 8HH (P1 RAM AIR IN ACTUATOR) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 28HH (P2 RAM AIR IN ACTUATOR) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
C. Inspection of the Air Inlet Flap before Deactivation
(1) Measure the air inlet gap.
(b) If the air inlet gap is 40 mm (1.5748 in.) or over then the air inlet is considered open.
(c) Make sure that the Air Inlet Flap is correctly adjusted (Ref. AMM TASK 21-61-51-820-001).
Subtask 21-61-00-010-057-C (1) Measure the air inlet gap.
NOTE: Do not apply pressure to the air inlet flap when you do the measurement.
(a) Use the RULER - STEEL to measure the air inlet gap.(b) If the air inlet gap is 40 mm (1.5748 in.) or over then the air inlet is considered open.
(c) Make sure that the Air Inlet Flap is correctly adjusted (Ref. AMM TASK 21-61-51-820-001).
D. Get Access
(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
(b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
4. Procedure(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
(b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
Subtask 21-61-00-040-050-A
A. Deactivation of the Air Inlet Flap
(1) Disconnect the electrical connector from the air inlet flap actuator 8HH (28HH) (Ref. AMM TASK 21-61-51-000-001).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Temporarily attach the loose electrical connector to the aircraft structure.
5. Close-up(1) Disconnect the electrical connector from the air inlet flap actuator 8HH (28HH) (Ref. AMM TASK 21-61-51-000-001).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Temporarily attach the loose electrical connector to the aircraft structure.
Subtask 21-61-00-865-063-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-61-00-869-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 8HH (P1 RAM AIR IN ACTUATOR) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 28HH (P2 RAM AIR IN ACTUATOR) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
B. Cockpit Effects
(1) On the upper ECAM DU the message AIR PACK 1 (PACK 2) REGUL FAULT will be displayed.
Subtask 21-61-00-410-056-C (1) On the upper ECAM DU the message AIR PACK 1 (PACK 2) REGUL FAULT will be displayed.
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel/s (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
(b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
(3) Make an entry in the log book to record the deactivation.
Subtask 21-61-00-862-052-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel/s (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
(b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
(3) Make an entry in the log book to record the deactivation.
Air Inlet Gap Measurement