TASK 21-61-00-040-002-A
Deactivation of the Air Inlet Flap in the Open Position


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the Left and the Right air inlet flaps.
FIN: 28HH
FIN: 8HH
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESYESNO1.01.01
1. Reason for the Job
MMEL 21-52-02A
AIR CONDITIONING PACK RAM AIR INLET FLAP
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
1
RULER - STEEL
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [28HH] (P2 RAM AIR IN ACTUATOR)
192KB
FOR [8HH] (P1 RAM AIR IN ACTUATOR)
191KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-61-51-000-001-A
Removal of the Air-Inlet Flap Actuator
TASK 21-61-51-820-001-A
Adjustment of the Air Inlet Flap
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
TASK 53-35-13-400-002-A
Installation of the Quick-Release Access Panels on the Belly Fairing Structure
3. Job Set-up
Subtask 21-61-00-861-053-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-61-00-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 8HH (P1 RAM AIR IN ACTUATOR)
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
** ON A/C NOT FOR ALL
FOR FIN: 28HH (P2 RAM AIR IN ACTUATOR)
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 21-61-00-220-050-B
C. Inspection of the Air Inlet Flap before Deactivation
   (1) Measure the air inlet gap.
NOTE: Do not apply pressure to the air inlet flap when you do the measurement.
     (a) Use the RULER - STEEL to measure the air inlet gap.
     (b) If the air inlet gap is 40 mm (1.5748 in.) or over then the air inlet is considered open.
     (c) Make sure that the Air Inlet Flap is correctly adjusted (Ref. AMM TASK 21-61-51-820-001).
Subtask 21-61-00-010-057-C
D. Get Access
   (1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
     (a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
     (b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
4. Procedure
Subtask 21-61-00-040-050-A
A. Deactivation of the Air Inlet Flap
   (1) Disconnect the electrical connector from the air inlet flap actuator 8HH (28HH) (Ref. AMM TASK 21-61-51-000-001).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Temporarily attach the loose electrical connector to the aircraft structure.
5. Close-up
Subtask 21-61-00-865-063-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 8HH (P1 RAM AIR IN ACTUATOR)
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
** ON A/C NOT FOR ALL
FOR FIN: 28HH (P2 RAM AIR IN ACTUATOR)
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 21-61-00-869-053-A
B. Cockpit Effects
   (1) On the upper ECAM DU the message AIR PACK 1 (PACK 2) REGUL FAULT will be displayed.
Subtask 21-61-00-410-056-C
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access panel/s (Ref. AMM TASK 53-35-13-400-002).
     (a) FOR [8HH] (P1 RAM AIR IN ACTUATOR)
     (b) FOR [28HH] (P2 RAM AIR IN ACTUATOR)
   (3) Make an entry in the log book to record the deactivation.
Subtask 21-61-00-862-052-A
D. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).