Removal of the Bypass Duct, Inlet


TASK 21-58-61-000-802-A
Removal of the Bypass Duct, Inlet


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS.
CAUTION: BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
ZONE: 191
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191
AIR CONDITIONING COMPT AND FAIRINGS
191CB, 191DB, 191KB, 192KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
F Bypass Duct, Inlet ** ON A/C NOT FOR ALL
F Bypass Duct, Inlet ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-58-61-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-58-61-865-060-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAN28
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAP28
** ON A/C NOT FOR ALL
122VUCSAS / CTRL1HWU17
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 21-58-61-865-053-A
DELETED
Subtask 21-58-61-941-051-A ** ON A/C NOT FOR ALL
D. Safety Precautions
   (1) In the cockpit, on AIR COND panel 30VU:
     (a) Make sure that the APU BLEED pushbutton switch is released (the OFF legend is on).
     (b) Make sure that the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
     (c) Make sure that the PACK 1 and the PACK 2 pushbutton switches are released (the OFF legends are on).
     (d) Make sure that the HOT AIR pushbutton switch is released (the OFF legend is on).
     (e) Put the WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) At access doors 191CB and 191DB:
     (a) On the LP and the HP ground connectors, put the WARNING NOTICE(S) in position to tell persons not to supply the ground air.
Subtask 21-58-61-010-052-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position at zone 191.
   (2) Remove applicable access panel(s) 191KB and/or 192KB (Ref. AMM TASK 53-35-13-000-002).
4. Procedure
Subtask 21-58-61-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Bypass Duct, Inlet
F Bypass Duct, Inlet ** ON A/C NOT FOR ALL
   (1) Remove the clamp (16).
   (2) Remove the nuts (12), the washers (11) and the screws (18).
   (3) Remove the nuts (9), washers (8), bonding straps (3) and (4) and screws (2).
   (4) Hold the duct (10) and remove the screws (13) and the washers (14).
   (5) Remove the duct (10) from the temperature control module (1) and discard the packings (15) and (17).
   (6) Remove and discard the seal (6).
   (7) Remove the seal (7).
   (8) Put the PLUG-BLANKING in each disconnected line end.
Subtask 21-58-61-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Bypass Duct, Inlet
F Bypass Duct, Inlet ** ON A/C NOT FOR ALL
   (1) Remove the clamp (16).
   (2) Remove the nuts (12), the washers (11) and the screws (18).
   (3) Remove the nuts (9), washers (8), screws (2), bonding straps (3) and (4) and heat shield (19).
   (4) Hold the duct (10) and remove the screws (13) and the washers (14).
   (5) Remove the duct (10) from the temperature control module (1).
   (6) Remove and discard the seals (6), (7), (15) and (17).
   (7) Put the PLUG-BLANKING in each disconnected line end.