W DOC AIRBUS | AMM A320F

Removal of the Ozone Converter Assy


TASK 21-58-42-000-001-A
Removal of the Ozone Converter Assy


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS.
FIN: 5101HM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
3. Job Set-up
Subtask 21-58-42-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-58-42-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAN28
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAP28
** ON A/C NOT FOR ALL
122VUCSAS / CTRL1HWU17
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 21-58-42-941-050-A ** ON A/C NOT FOR ALL
C. Safety Precautions
   (1) On the panel 30VU, make sure that:
  • The APU BLEED pushbutton switch is in the off position (the ON legend is off).
  • The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
     (a) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
Subtask 21-58-42-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 191.
   (2) Remove the access panel 191BB (Ref. AMM TASK 53-35-13-000-002).
4. Procedure
Subtask 21-58-42-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Ozone Converter Assembly
F Ozone Converter (5101HM) ** ON A/C NOT FOR ALL
   (1) Remove the insulation (17) of the ozone converter (16) as necessary.
   (2) Remove the nut (4), the washer (5), the bonding strap (8), the washer (6) and the screw (7).
   (3) Remove the clamps (3) and (9).
   (4) Make sure that a person holds the ozone converter (16) while you remove it.
   (5) Remove the clamps (13) and (20) and the bearing shells (14), (15), (18) and (19).
   (6) Remove the ozone converter (16).
   (7) Remove and discard the seals (2) and (10).
   (8) Put PLUG - BLANKING on the disconnected line ends (1) and (11) and on the ozone converter (16).
[Rev.10 from 2021] 2026.04.02 06:11:35 UTC