Removal of the Ozone Converter Assy
TASK 21-58-42-000-001-A
Removal of the Ozone Converter Assy
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-58-42-861-050-A ** ON A/C NOT FOR ALL Subtask 21-58-42-865-050-A ** ON A/C NOT FOR ALL
Subtask 21-58-42-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:35 UTC
Removal of the Ozone Converter Assy
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
FIN: 5101HM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191BB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
Subtask 21-58-42-861-050-A ** ON A/C NOT FOR ALL Subtask 21-58-42-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-58-42-941-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | IGGS/CTRL | 7YA | N28 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | IGGS/CTRL | 7YA | P28 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | CSAS / CTRL | 1HW | U17 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
C. Safety Precautions
(1) On the panel 30VU, make sure that:
(2) On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
Subtask 21-58-42-010-050-A ** ON A/C NOT FOR ALL (1) On the panel 30VU, make sure that:
- The APU BLEED pushbutton switch is in the off position (the ON legend is off).
- The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
(2) On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
D. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 191.
(2) Remove the access panel 191BB (Ref. AMM TASK 53-35-13-000-002).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 191.
(2) Remove the access panel 191BB (Ref. AMM TASK 53-35-13-000-002).
Subtask 21-58-42-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Ozone Converter Assembly
(1) Remove the insulation (17) of the ozone converter (16) as necessary.
(2) Remove the nut (4), the washer (5), the bonding strap (8), the washer (6) and the screw (7).
(3) Remove the clamps (3) and (9).
(4) Make sure that a person holds the ozone converter (16) while you remove it.
(5) Remove the clamps (13) and (20) and the bearing shells (14), (15), (18) and (19).
(6) Remove the ozone converter (16).
(7) Remove and discard the seals (2) and (10).
(8) Put PLUG - BLANKING on the disconnected line ends (1) and (11) and on the ozone converter (16).
(1) Remove the insulation (17) of the ozone converter (16) as necessary.
(2) Remove the nut (4), the washer (5), the bonding strap (8), the washer (6) and the screw (7).
(3) Remove the clamps (3) and (9).
(4) Make sure that a person holds the ozone converter (16) while you remove it.
(5) Remove the clamps (13) and (20) and the bearing shells (14), (15), (18) and (19).
(6) Remove the ozone converter (16).
(7) Remove and discard the seals (2) and (10).
(8) Put PLUG - BLANKING on the disconnected line ends (1) and (11) and on the ozone converter (16).
Ozone Converter (5101HM)