Operational Test of the Conditioned Service Air System without Bleed Air
TASK 21-58-00-710-001-A
Operational Test of the Conditioned Service Air System without Bleed Air
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 21-58-00-861-050-A ** ON A/C NOT FOR ALL Subtask 21-58-00-865-050-A ** ON A/C NOT FOR ALL
Subtask 21-58-00-710-050-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 21-58-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:33 UTC
Operational Test of the Conditioned Service Air System without Bleed Air
ZONE: 210
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-002-A | Procedure to Get Access to the SYSTEM REPORT/TEST/AIR COND Page |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 21-58-00-861-050-A ** ON A/C NOT FOR ALL Subtask 21-58-00-865-050-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-58-00-860-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM4 (HEAT EXCHANGER UNIT) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 11HM4 (HEAT EXCHANGER UNIT) | |||
| 121VU | IGGS/CTRL | 7YA | N28 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | IGGS/CTRL | 7YA | P28 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | CSAS / CTRL | 1HW | U17 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
C. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) On the overhead panel, on ADIRS MSU panel 41VU, set the three OFF/NAV/ATT selector switches to the NAV position.
(3) On the MCDU get the SYSTEM REPORT/TEST/AIR COND Page (Ref. AMM TASK 31-32-00-860-002).
4. Procedure(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) On the overhead panel, on ADIRS MSU panel 41VU, set the three OFF/NAV/ATT selector switches to the NAV position.
(3) On the MCDU get the SYSTEM REPORT/TEST/AIR COND Page (Ref. AMM TASK 31-32-00-860-002).
Subtask 21-58-00-710-050-A ** ON A/C NOT FOR ALL
WARNING:
MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM AIR OUTLET FLAPS. MOVEMENT OF THE RAM AIR OUTLET FLAPS AND HOT EXHAUST GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
A. Operational Test of the Conditioned Service Air System without bleed air | ACTION | RESULT |
|---|---|
| 1.On the AIRCOND menu page: | On the MCDU: |
|
|
| 2.On the CSAS/IGGS menu page: | |
|
|
| 3.On the CSAS/IGGS TESTS page: | |
|
|
| 4.On the TEST W/O BLEED page: | |
| |
|
Subtask 21-58-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(3) On the overhead panel, on ADIRS MSU 41VU:
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(3) On the overhead panel, on ADIRS MSU 41VU:
- Set the three OFF/NAV/ATT selector switches to the OFF position.