W DOC AIRBUS | AMM A320F

Operational Test of the Emergency Ram-Air Inlet System


TASK 21-55-00-040-001-A
Operational Test of the Emergency Ram-Air Inlet System


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.40.41
1. Reason for the Job
MMEL 21-07-01-06A
EMERGENCY RAM AIR INLET INDICATION ON THE BLEED SD PAGE (FAA ONLY)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 34-10-00-860-002-A
ADIRS Start Procedure
TASK 34-10-00-860-005-A
ADIRS Stop Procedure
3. Job Set-up
Subtask 21-55-00-861-052-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-55-00-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/RAM/AIR/INLET1HZD10
49VUAIR COND/CAB/PRESS/CTL11HLD09
122VUAIR COND/CAB PRESS/CTL/22HLY22
Subtask 21-55-00-860-051-A
C. Aircraft Maintenance Configuration
   (1) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (2) Make sure that the PRESS page shows on the ECAM lower display unit.
   (3) On the AIR COND panel 30VU:
  • make sure that the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).
   (4) Do the start procedure of the ADIRS (Ref. AMM TASK 34-10-00-860-002).
4. Procedure
Subtask 21-55-00-040-050-A
WARNING: MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM AIR INLET FLAPS. THE MOVEMENT OF THE RAM AIR INLET FLAPS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE OUTFLOW VALVES ARE CLEAR. MOVEMENT OF THE OUTFLOW VALVES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
A. Operational Test
ACTION
RESULT
1.On the AIR COND panel 30VU:
  • lift the black guard and push the RAM AIR pushbutton-switch to the on position.
On the AIR COND panel 30VU:
  • in the RAM AIR pushbutton-switch the ON legend comes on.

On the ECAM upper display unit:
  • the green RAM AIR ON message comes on.

On the ECAM lower display unit:
  • the outflow valve symbol shows approx. 50 DEG. open when the differential pressure in the fuselage is less than 1 psi.
2.On the AIR COND panel 30VU:
  • lift the black guard and push the RAM AIR pushbutton-switch to the off position.
On the AIR COND panel 30VU:
  • on the RAM AIR pushbutton-switch the ON legend goes off.

On the ECAM lower display unit:
  • the outflow valve symbol moves to the fully open position.

On the ECAM upper display unit:
  • the green RAM AIR ON message goes off.
5. Close-up
Subtask 21-55-00-860-052-A
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
   (2) Do the ADIRS stop procedure (Ref. AMM TASK 34-10-00-860-005).
Subtask 21-55-00-941-050-A
B. Remove the WARNING NOTICE(S).
Subtask 21-55-00-862-052-A
C. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:11:32 UTC