Installation of the Water Injector
TASK 21-52-42-400-001-A
Installation of the Water Injector
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-52-42-860-050-A
Subtask 21-52-42-420-050-A
Subtask 21-52-42-865-052-A
[Rev.10 from 2021]
2026.04.02 06:47:31 UTC
Installation of the Water Injector
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the water injectors 20HM and 21HM.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | Torque wrench: range to between 1.75 and 1.65 m.daN (12.91 and 12.17 lbf.ft ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [20HM] (P1 WATER INJECTOR) | |
| 191KB | |
| FOR [21HM] (P2 WATER INJECTOR) | |
| 192KB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
| TASK 53-35-13-400-002-A | Installation of the Quick-Release Access Panels on the Belly Fairing Structure |
Subtask 21-52-42-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On the panel 30VU make sure that:
(a) The APU BLEED pushbutton switch is in the off position (the ON legend is off).
(b) The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
(c) The warning notice to tell persons not to operate these pushbutton switches is in position.
(3) Make sure that on the HP ground connector the warning notice to tell persons not to supply the ground air is in position.
(4) Make sure that the access panel(s) is/are removed (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [20HM] (P1 WATER INJECTOR)
Subtask 21-52-42-865-051-A (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On the panel 30VU make sure that:
(a) The APU BLEED pushbutton switch is in the off position (the ON legend is off).
(b) The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
(c) The warning notice to tell persons not to operate these pushbutton switches is in position.
(3) Make sure that on the HP ground connector the warning notice to tell persons not to supply the ground air is in position.
(4) Make sure that the access panel(s) is/are removed (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [20HM] (P1 WATER INJECTOR)
- 191KB,
- 192KB.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 20HM (P1 WATER INJECTOR) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 21HM (P2 WATER INJECTOR) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
Subtask 21-52-42-420-050-A
A. Installation of the Water Injector
(1) Clean the component interfaces and the adjacent area.
(2) Put the washer (6) and the water injector (2) in position on the inlet plenum (1).
(3) Make sure that the water injector is in the correct position and install the washers (5) and the bolts (4).
(5) Connect the water hose (3) to the water injector (2).
(6) TORQUE the water hose (3) connector to between 1.75 and 1.65 m.daN (12.91 and 12.17 lbf.ft )
.
(7) Make sure that the work area is clean and clear of tools and other items.
5. Close-up(1) Clean the component interfaces and the adjacent area.
(2) Put the washer (6) and the water injector (2) in position on the inlet plenum (1).
(3) Make sure that the water injector is in the correct position and install the washers (5) and the bolts (4).
NOTE: The water injector nozzle must point in the direction of the airflow.
(4) Remove the blanking plugs from the disconnected line ends. (5) Connect the water hose (3) to the water injector (2).
(6) TORQUE the water hose (3) connector to between 1.75 and 1.65 m.daN (12.91 and 12.17 lbf.ft )
. (7) Make sure that the work area is clean and clear of tools and other items.
Subtask 21-52-42-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-52-42-410-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 20HM (P1 WATER INJECTOR) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 21HM (P2 WATER INJECTOR) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
B. Close Access
(1) Install the access panel/s (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [20HM] (P1 WATER INJECTOR)
(b) FOR [21HM] (P2 WATER INJECTOR)
(2) Remove the WARNING NOTICE(S).
Subtask 21-52-42-862-050-A (1) Install the access panel/s (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [20HM] (P1 WATER INJECTOR)
(b) FOR [21HM] (P2 WATER INJECTOR)
(2) Remove the WARNING NOTICE(S).
Water Injector