Removal of the Pipe Assembly between the Anti-Ice Valve (if installed), the Bypass Valve and the Air Cycle Machine
TASK 21-52-23-000-002-A
Removal of the Pipe Assembly between the Anti-Ice Valve (if installed), the Bypass Valve and the Air Cycle Machine
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-52-23-861-053-A Subtask 21-52-23-865-053-A
Subtask 21-52-23-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:27 UTC
Removal of the Pipe Assembly between the Anti-Ice Valve (if installed), the Bypass Valve and the Air Cycle Machine
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure for the removal of the pipe assembly is the same for the left and right side.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [10HM] (PACK 1-AIR CONDITIONING) | |
| 191KB | |
| FOR [11HM] (PACK 2-AIR CONDITIONING) | |
| 192KB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
Subtask 21-52-23-861-053-A Subtask 21-52-23-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-52-23-010-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM (PACK 1AIR CONDITIONING) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 11HM (PACK 2AIR CONDITIONING) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
C. Get Access
(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002):
(a) FOR [10HM] (PACK 1-AIR CONDITIONING)
(b) FOR [11HM] (PACK 2-AIR CONDITIONING)
Subtask 21-52-23-941-051-A (1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002):
(a) FOR [10HM] (PACK 1-AIR CONDITIONING)
(b) FOR [11HM] (PACK 2-AIR CONDITIONING)
D. Safety Precautions
(1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that:
(2) On the HP ground connector, put the WARNING NOTICE(S) in position to tell persons not to supply the ground air.
4. Procedure(1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that:
- The APU BLEED pushbutton switch is released (the ON legend is off).
- The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
(2) On the HP ground connector, put the WARNING NOTICE(S) in position to tell persons not to supply the ground air.
Subtask 21-52-23-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Pipe Assembly
(1) Remove the clamps (5) and (9).
(2) Carefully remove the pipe assembly (8).
(3) Remove and discard the packings (2) and (3).
(4) Remove and discard the seal (4).
(5) Put the PLUG-BLANKING in each disconnected line end.
Subtask 21-52-23-020-051-B ** ON A/C NOT FOR ALL (1) Remove the clamps (5) and (9).
(2) Carefully remove the pipe assembly (8).
(3) Remove and discard the packings (2) and (3).
(4) Remove and discard the seal (4).
(5) Put the PLUG-BLANKING in each disconnected line end.
A. Removal of the Pipe Assembly
(1) Remove the clamp (9).
(2) Carefully remove the pipe assembly (8).
(3) Remove and discard the packings (2).
(4) Remove and discard the seal (6).
(5) Put the PLUG-BLANKING in each disconnected line end.
(1) Remove the clamp (9).
(2) Carefully remove the pipe assembly (8).
(3) Remove and discard the packings (2).
(4) Remove and discard the seal (6).
(5) Put the PLUG-BLANKING in each disconnected line end.
Pipe Assembly.