Removal of the Fan Plenum Chamber


TASK 21-52-22-000-001-A
Removal of the Fan Plenum Chamber


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for fan plenum chambers 10HM5 and 11HM5.
FIN: 10HM5
FIN: 11HM5
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
COVER - PROTECTION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10HM5] (PLENUM CHAMBER)
191KB
FOR [11HM5] (PLENUM CHAMBER)
192KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-52-23-000-001-A
Removal of the Pipe Assembly between the Main Heat Exchanger and the Air Cycle Machine
TASK 21-52-24-000-001-A
Removal of the Heat Exchanger Unit (from the Aircraft)
TASK 21-52-24-000-001-A-01
Removal of the Heat Exchanger Unit (From the Air Conditioning Pack)
TASK 21-61-52-000-003-A
Removal of the Ram-Air Outlet
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
F Fan Plenum Chamber 10HM5 (11HM5) ** ON A/C NOT FOR ALL
F Fan Plenum Chamber 10HM5 (11HM5) ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-52-22-861-051-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-52-22-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 10HM5 (PLENUM CHAMBER)
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
** ON A/C NOT FOR ALL
FOR FIN: 11HM5 (PLENUM CHAMBER)
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 21-52-22-010-050-A
C. Get Access
   (1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002):
     (a) FOR [10HM5] (PLENUM CHAMBER)
     (b) FOR [11HM5] (PLENUM CHAMBER)
Subtask 21-52-22-941-050-A
D. Safety Precautions
   (1) On the overhead panel, on AIR COND panel 30VU:
     (a) Make sure that:
  • The APU BLEED pushbutton switch is released (the ON legend is off).
  • The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
     (b) Put the WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP ground connector, put the WARNING NOTICE(S) in position to tell persons not to supply the ground air.
4. Procedure
Subtask 21-52-22-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Fan Plenum Chamber
   (1) Remove the ram air outlet(s) (Ref. AMM TASK 21-61-52-000-003).
   (2) Disconnect and remove the clamp (4).
   (3) Remove the bellow (5).
   (4) Disconnect and remove the clamp (9).
   (5) Disconnect the sleeve (10).
   (6) Disconnect the bonding strap (8).
NOTE: This work step is only applicable to fan plenum-chamber part-numbers 1816A0000-01, 749A0000-02 Amdt B, 2056A0000-02 Amdt A, 2056B0000-01 Amdt A, 2056C0000-01 and 2056C0000-02.
   (7) Remove the screw (2), the washer (3) and the bonding strap (8).
   (8) Remove the screws (2), the washers (3) and the fan plenum chamber (1).
   (9) If the gasket (6) is installed on the fan plenum chamber (1), remove the gasket (6).
   (10) Put the COVER - PROTECTION on the cooling elements of the primary heat exchanger (7).
Subtask 21-52-22-020-051-C ** ON A/C NOT FOR ALL
A. Removal of the Fan Plenum Chamber
   (1) Remove the ram air outlet/s (Ref. AMM TASK 21-61-52-000-003).
   (2) Remove the pipe assembly/ies (Ref. AMM TASK 21-52-23-000-001).
   (3) Remove heat exchanger unit/s 10HM4 (11HM4) (Ref. AMM TASK 21-52-24-000-001).
NOTE: It is not necessary to remove the inlet plenum at this time.
   (4) Disconnect the bonding strap (7):
NOTE: This work step is only applicable to fan plenum chamber P/N 1816A0000-01.
     (a) Remove the nut (10), the washer (9) and the screw (8) and disconnect the bonding strap (7).
   (5) Remove the screws (1), the washers (2) and the fan plenum chamber (3).
   (6) Put a COVER - PROTECTION on the cooling elements of the primary heat exchanger (5).