General Visual Inspection of the Compressor Tubes and Duct for Signs of Delamination
TASK 21-52-00-200-807-A
General Visual Inspection of the Compressor Tubes and Duct for Signs of Delamination
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-52-00-861-065-A Subtask 21-52-00-865-088-A
Subtask 21-52-00-210-062-A
Subtask 21-52-00-865-089-A
[Rev.10 from 2021]
2026.04.02 06:48:39 UTC
General Visual Inspection of the Compressor Tubes and Duct for Signs of Delamination
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
NOTE: This procedure is valid for the PN 1263A0000-02/-03 and for PN 1814A0000-02.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191 | AIR CONDITIONING COMPT AND FAIRINGS |
| 192 | AIR CONDITIONING COMPT AND FAIRINGS |
| FOR [10HM1] (MACHINE-AIR CYCLE) | |
| 191KB | |
| FOR [11HM1] (MACHINE-AIR CYCLE) | |
| 192KB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-52-21-000-001-A | Removal of the Air Cycle Machine |
| TASK 21-52-21-000-802-A | Removal of the Compressor Tubes and Duct |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
| TASK 53-35-13-400-002-A | Installation of the Quick-Release Access Panels on the Belly Fairing Structure |
Subtask 21-52-00-861-065-A Subtask 21-52-00-865-088-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-52-00-941-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM1 (MACHINEAIR CYCLE) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 11HM1 (MACHINEAIR CYCLE) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
C. Safety Precautions
(1) On the AIR COND panel 30VU make sure that:
(2) On the access door 191DB on the HP ground connector put a WARNING NOTICE(S) not to supply the ground air.
Subtask 21-52-00-010-074-A (1) On the AIR COND panel 30VU make sure that:
- The APU BLEED P/BSW is in the OFF position (the ON legend is off) and,
- The ENGINE 1 and 2 BLEED P/BSW are in the off position (the OFF legends are on).
(2) On the access door 191DB on the HP ground connector put a WARNING NOTICE(S) not to supply the ground air.
D. Get Access
(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM1] (MACHINE-AIR CYCLE)
191KB,
(b) FOR [11HM1] (MACHINE-AIR CYCLE)
192KB.
4. Procedure(1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM1] (MACHINE-AIR CYCLE)
191KB,
(b) FOR [11HM1] (MACHINE-AIR CYCLE)
192KB.
Subtask 21-52-00-210-062-A
A. General Visual Inspection of the Compressor Tubes and Duct
(1) Do a general visual inspection of the return air tube (1), the anti icing tube (2) and the blanking duct (3) for signs of delamination or cracks.
(2) If any of the tubes or duct is cracked or missing, replace the air cycle machine (Ref. AMM TASK 21-52-21-000-001).
(3) If any of the tubes or duct shows signs of delamination or hardening, replace the tube or duct (Ref. AMM TASK 21-52-21-000-802).
5. Close-up(1) Do a general visual inspection of the return air tube (1), the anti icing tube (2) and the blanking duct (3) for signs of delamination or cracks.
(2) If any of the tubes or duct is cracked or missing, replace the air cycle machine (Ref. AMM TASK 21-52-21-000-001).
(3) If any of the tubes or duct shows signs of delamination or hardening, replace the tube or duct (Ref. AMM TASK 21-52-21-000-802).
Subtask 21-52-00-865-089-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-52-00-410-071-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM1 (MACHINEAIR CYCLE) | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 11HM1 (MACHINEAIR CYCLE) | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [10HM1] (MACHINE-AIR CYCLE)
191KB.
(b) FOR [11HM1] (MACHINE-AIR CYCLE)
192KB.
(3) Remove the WARNING NOTICE(S).
Subtask 21-52-00-862-063-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [10HM1] (MACHINE-AIR CYCLE)
191KB.
(b) FOR [11HM1] (MACHINE-AIR CYCLE)
192KB.
(3) Remove the WARNING NOTICE(S).
Compressor tubes and duct - Component Location