W DOC AIRBUS | AMM A320F

Remove Ozone Filter (Converter) for in Shop Functional Check


TASK 21-51-41-920-001-A
Remove Ozone Filter (Converter) for in Shop Functional Check


ZONE: 190
FIN: 100HM
FIN: 101HM
1. Reason for the Job
Refer to the MPD TASK: 215141-01
REMOVE OZONE CONVERTER FOR IN SHOP FUNCTIONAL CHECK
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
190
BELLY FAIR, AIR CONDITIONING & HYD COMPT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 21-51-41-000-001-A
Removal of the Ozone Filter
TASK 21-51-41-400-001-A
Installation of the Ozone Filter
3. Job Set-up
Subtask 21-51-41-010-051-A
A. Not applicable.
4. Procedure
Subtask 21-51-41-020-052-A
A. Remove the ozone filter (Ref. AMM TASK 21-51-41-000-001).
Subtask 21-51-41-920-050-A
B. Send the removed ozone filter to the manufacturer for the functional check.
Subtask 21-51-41-420-052-A
C. Install a serviceable or new ozone filter (Ref. AMM TASK 21-51-41-400-001).
[Rev.10 from 2021] 2026.04.02 06:11:22 UTC