W DOC AIRBUS | AMM A320F

Operational Test of the Flow Control Valves Closing


TASK 21-51-00-710-003-A
Operational Test of the Flow Control Valves Closing


WARNING: MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
FIN: 11HB ** ON A/C NOT FOR ALL
FIN: 23HB ** ON A/C NOT FOR ALL
FIN: 24HB ** ON A/C NOT FOR ALL
FIN: 8HB ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 12-33-21-618-001-A-01
Pre-conditioning through the HP Ground Connection
TASK 12-33-21-618-001-A-02
Pre-conditioning with the APU
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 21-51-00-861-053-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-51-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
Subtask 21-51-00-860-053-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Open the avionics-bay access door 811.
   (2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
   (3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (4) Make sure that the BLEED page is shown on the ECAM lower display unit.
   (5) On the panel 30VU make sure that:

  • the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on),

  • the PACK FLOW selector is in the NORM position and,

  • the HOT AIR pushbutton switch is in the off position (the OFF legend is on).
Subtask 21-51-00-860-053-B ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Open the avionics-bay access door 811.
   (2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
   (3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (4) Make sure that the BLEED page is shown on the ECAM lower display unit.
   (5) On the panel 30VU make sure that:

  • the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on),

  • the ECON FLOW pushbutton switch is in the off position (the ON legend is off) and,

  • the HOT AIR pushbutton switch is in the off position (the OFF legend is on).
Subtask 21-51-00-618-051-A
D. Do the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001) or with the APU (Ref. AMM TASK 12-33-21-618-001).
4. Procedure
WARNING: MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM AIR OUTLETS. HOT EXHAUST GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
Subtask 21-51-00-710-052-A
A. Operational Test of the Flow Control Valves Closing
ACTION
RESULT
1.On the panel 30VU:
  • push the PACK 1 and PACK 2 pushbutton switches to the on position.
On the panel 30VU:
  • the OFF legends on the PACK 1 and PACK 2 pushbutton switches go off.

On the ECAM lower display unit:
  • the L and R flow control valve symbols open.
  • push the PACK 1 and PACK 2 pushbutton switches to the off position..
On the panel 30VU:
  • the OFF legends on the PACK 1 and PACK 2 pushbutton switches come on.

On the ECAM lower display panel:
  • the L and R flow control valve symbols close.
5. Close-up
Subtask 21-51-00-860-054-A
A. Aircraft Maintenance Configuration
   (1) Stop the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001).
   (2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (3) Remove the WARNING NOTICE(S).
   (4) Close the avionics-bay access door 811.
Subtask 21-51-00-862-052-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:06:00 UTC