Removal of the AFT Cargo Heat Controller
TASK 21-43-34-000-002-A
Removal of the AFT Cargo Heat Controller
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-43-34-861-051-A ** ON A/C NOT FOR ALL Subtask 21-43-34-865-053-A ** ON A/C NOT FOR ALL
Subtask 21-43-34-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:20 UTC
Removal of the AFT Cargo Heat Controller
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 21-43-34-861-051-A ** ON A/C NOT FOR ALL Subtask 21-43-34-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-43-34-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
C. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 811.
(2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002)
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 811.
(2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002)
Subtask 21-43-34-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the AFT Cargo Heat Controller
(1) Loosen the nut (9).
(2) Lower the nut (9).
(3) Pull the AFT cargo heat controller (6) on its rack (8) to disconnect the electrical connectors (7).
(4) Remove the AFT cargo heat controller (6) from the rack (8).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Loosen the nut (9).
(2) Lower the nut (9).
(3) Pull the AFT cargo heat controller (6) on its rack (8) to disconnect the electrical connectors (7).
(4) Remove the AFT cargo heat controller (6) from the rack (8).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
AFT Cargo Heat Controller