W DOC AIRBUS | AMM A320F

Removal of the FWD Cargo Heat Controller


TASK 21-43-34-000-001-A
Removal of the FWD Cargo Heat Controller


ZONE: 121
FIN: 1HC ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
Subtask 21-43-34-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-43-34-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
Subtask 21-43-34-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 811.
   (2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 21-43-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the FWD Cargo Heat Controller
   (1) Loosen the nut (4).
   (2) Lower the nut (4).
   (3) Pull the FWD cargo heat controller (1) on its rack (3) to disconnect the electrical connectors (2).
   (4) Remove the FWD cargo heat controller (1) from its rack (3).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.02 06:45:53 UTC