W DOC AIRBUS | AMM A320F

Removal of the Aft Cargo-Compartment Temperature-Sensors


TASK 21-43-15-000-001-A
Removal of the Aft Cargo-Compartment Temperature-Sensors


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 13HC ** ON A/C NOT FOR ALL
FIN: 14HC ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
FOR [13HC] (AFT CARGO DUCT SENSOR)
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
FOR [14HC] (AFT CARGO COMP SENSOR)
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
826
FOR [13HC] (AFT CARGO DUCT SENSOR)
151EW
151UW
FOR [14HC] (AFT CARGO COMP SENSOR)
161DW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [13HC] (AFT CARGO DUCT SENSOR)
TASK 25-55-11-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59
FOR [14HC] (AFT CARGO COMP SENSOR)
TASK 25-55-11-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59
3. Job Set-up
Subtask 21-43-15-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-43-15-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
122VUAIR COND/AFT CARGO VENT/FAN30HNS22
Subtask 21-43-15-865-059-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
122VUAIR COND/AFT CARGO VENT/FAN30HNS22
Subtask 21-43-15-941-050-C ** ON A/C NOT FOR ALL
D. Safety Precautions
   (1) On the panel 30VU:
     (a) Make sure that:
  • the APU BLEED pushbutton switch is in the off position (the ON legend is off) and,
  • the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
     (b) Put a warning notice in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and the LP ground connectors put a warning notice in position to tell persons not to supply the ground air.
Subtask 21-43-15-010-050-C ** ON A/C NOT FOR ALL
E. Get Access
   (1) Open the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo-compartment door 826.
   (3) Remove the access panel:
     (a) FOR [13HC] (AFT CARGO DUCT SENSOR)
     (b) FOR [14HC] (AFT CARGO COMP SENSOR)
Subtask 21-43-15-010-050-D ** ON A/C NOT FOR ALL
E. Get Access
   (1) Open the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo-compartment door 826.
   (3) Remove the access panel:
     (a) FOR [13HC] (AFT CARGO DUCT SENSOR)
     (b) FOR [14HC] (AFT CARGO COMP SENSOR)
4. Procedure
Subtask 21-43-15-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Temperature Sensors
   (1) FOR [13HC] (AFT CARGO DUCT SENSOR)
     (a) Disconnect the electrical connector (1).
     (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (c) Remove and discard the locking wire from the temperature sensor (2).
     (d) Remove the temperature sensor (2) and the O-ring (3).
     (e) Put the PLUG-BLANKING in each disconnected line end.
   (2) FOR [14HC] (AFT CARGO COMP SENSOR)
     (a) Disconnect the electrical connector (5).
     (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (c) Remove and discard the locking wire from the temperature sensor (6).
     (d) Remove the temperature sensor (6) and the O-ring (7).
     (e) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 06:48:20 UTC