W DOC AIRBUS | AMM A320F

Installation of the Duct Temperature Sensor (Extraction Duct)


TASK 21-43-14-400-003-A
Installation of the Duct Temperature Sensor (Extraction Duct)


FIN: 4HC ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
132KW, 825
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
O-RING
AIPC 21-43-02-03-010
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 21-43-14-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-43-14-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at the FWD Cargo door 825.
   (2) Make sure that the FWD cargo access door 825 is open (Ref. AMM TASK 52-30-00-860-001).
   (3) Make sure that the access panel 132KW is removed.
Subtask 21-43-14-865-055-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
4. Procedure
Subtask 21-43-14-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Duct Temperature Sensor
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Clean the component interfaces and the adjacent area.
   (3) Install the duct temperature sensor (2) and the AIPC 21-43-02-03-010 O-RING (3) in the extract duct (4).
   (4) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (5) Make sure that all the electrical connections are clean and in the correct condition.
   (6) Connect the electrical connector (1) to the duct temperature sensor (2).
5. Close-up
Subtask 21-43-14-865-056-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
Subtask 21-43-14-410-051-A ** ON A/C NOT FOR ALL
Subtask 21-43-14-862-051-A ** ON A/C NOT FOR ALL
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).