Installation of the Duct Temperature Sensor (Inlet Duct)
TASK 21-43-14-400-002-A
Installation of the Duct Temperature Sensor (Inlet Duct)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 21-43-14-860-050-A ** ON A/C NOT FOR ALL
Subtask 21-43-14-420-050-A ** ON A/C NOT FOR ALL
Subtask 21-43-14-865-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:19 UTC
Installation of the Duct Temperature Sensor (Inlet Duct)
FIN: 3HC ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 131MW, 825 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | O-RING | AIPC 21-43-02-03-010 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-43-14-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-43-14-010-052-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at the FWD cargo door 825.
(2) Make sure that the FWD cargo access door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the access panel 131MW is removed.
Subtask 21-43-14-865-052-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at the FWD cargo door 825.
(2) Make sure that the FWD cargo access door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the access panel 131MW is removed.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
Subtask 21-43-14-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Duct Temperature Sensor
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Install the duct temperature sensor (2) and the AIPC 21-43-02-03-010 O-RING (3) in the inlet duct (4).
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Remove the CAP-BLANKING from each electrical connector and receptacle.
(6) Connect the electrical connector (1) to the duct temperature sensor (2).
5. Close-up(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Install the duct temperature sensor (2) and the AIPC 21-43-02-03-010 O-RING (3) in the inlet duct (4).
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Remove the CAP-BLANKING from each electrical connector and receptacle.
(6) Connect the electrical connector (1) to the duct temperature sensor (2).
Subtask 21-43-14-865-053-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-43-14-410-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 131MW.
(3) Close the FWD cargo door 825.
(4) Remove the access platform(s).
Subtask 21-43-14-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 131MW.
(3) Close the FWD cargo door 825.
(4) Remove the access platform(s).
Duct Temperature Sensor (Inlet Duct)