Removal of the Duct Temperature Sensor (Extraction Duct)


TASK 21-43-14-000-003-A
Removal of the Duct Temperature Sensor (Extraction Duct)


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 4HC ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
132KW, 825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 21-43-14-861-051-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-43-14-865-054-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
Subtask 21-43-14-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the FWD cargo door 825.
   (2) Open the FWD cargo access door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Remove the access panel 132KW.
4. Procedure
Subtask 21-43-14-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Duct Temperature Sensor
   (1) Disconnect the electrical connector (1) from the duct temperature sensor (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the duct temperature sensor (2) from the extract duct (4).
   (4) Remove the O-ring (3).