Cleaning of the Cargo Compartment Duct-Temperature Sensors and the Cargo Compartment-Temperature Sensor
TASK 21-43-00-100-001-A
Cleaning of the Cargo Compartment Duct-Temperature Sensors and the Cargo Compartment-Temperature Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 21-43-00-861-064-A ** ON A/C NOT FOR ALL Subtask 21-43-00-865-065-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-100-051-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:19 UTC
Cleaning of the Cargo Compartment Duct-Temperature Sensors and the Cargo Compartment-Temperature Sensor
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the duct temperature sensors 3HC, 4HC and/or 13HC and the compartment temperature sensor 14HC.
FIN: 13HC ** ON A/C NOT FOR ALL
FIN: 14HC ** ON A/C NOT FOR ALL
FIN: 3HC ** ON A/C NOT FOR ALL
FIN: 4HC ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 14HC ** ON A/C NOT FOR ALL
FIN: 3HC ** ON A/C NOT FOR ALL
FIN: 4HC ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | BRUSH - NON METALLIC, SOFT |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 826 | |
| 825 | |
| FOR [13HC] (AFT CARGO DUCT SENSOR) | |
| 151EW | |
| FOR [14HC] (AFT CARGO COMP SENSOR) | |
| 151BC | |
| FOR [3HC] (FWD CARGO DUCT SENSOR) | |
| 132KW | |
| FOR [4HC] (FWD CARGO COMP SENSOR) | |
| 131MW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-43-14-000-002-A | Removal of the Duct Temperature Sensor (Inlet Duct) |
| TASK 21-43-14-000-003-A | Removal of the Duct Temperature Sensor (Extraction Duct) |
| TASK 21-43-14-400-002-A | Installation of the Duct Temperature Sensor (Inlet Duct) |
| TASK 21-43-14-400-003-A | Installation of the Duct Temperature Sensor (Extraction Duct) |
| TASK 21-43-15-000-001-A | Removal of the Aft Cargo-Compartment Temperature-Sensors |
| TASK 21-43-15-400-001-A | Installation of the Aft Cargo-Compartment Temperature-Sensors |
| TASK 21-61-00-710-001-A | Operational Test of the Pack Temperature-Control System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-55-11-000-002-A | Removal of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 25-55-11-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-55-11-400-002-A | Installation of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 25-55-11-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-43-00-861-064-A ** ON A/C NOT FOR ALL Subtask 21-43-00-865-065-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-43-00-865-077-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 3HC (FWD CARGO DUCT SENSOR) | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
| FOR FIN: 4HC (FWD CARGO COMP SENSOR) | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-43-00-865-091-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 13HC (AFT CARGO DUCT SENSOR) | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
| FOR FIN: 14HC (AFT CARGO COMP SENSOR) | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
D. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-43-00-941-061-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
E. Safety Precautions
(1) On the panel 30VU:
(a) Make sure that the APU BLEED and the ENG BLEED/1(2) pushbutton switches are released.
(b) Put a warning notice to tell persons not to operate these pushbutton switches.
(2) On the HP and the LP ground connectors:
(a) Put a warning notice to tell persons not to supply the ground air.
Subtask 21-43-00-010-060-A ** ON A/C NOT FOR ALL (1) On the panel 30VU:
(a) Make sure that the APU BLEED and the ENG BLEED/1(2) pushbutton switches are released.
(b) Put a warning notice to tell persons not to operate these pushbutton switches.
(2) On the HP and the LP ground connectors:
(a) Put a warning notice to tell persons not to supply the ground air.
F. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the Fwd cargo-compartment door 825.
(2) Open the Fwd cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel(s) (Ref. AMM TASK 25-54-12-000-003):
(a) FOR [3HC] (FWD CARGO DUCT SENSOR)
(4) Remove the duct temperature sensor 3HC (Ref. AMM TASK 21-43-14-000-002).
(5) Remove the duct temperature sensor 4HC (Ref. AMM TASK 21-43-14-000-003).
Subtask 21-43-00-010-060-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the Fwd cargo-compartment door 825.
(2) Open the Fwd cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel(s) (Ref. AMM TASK 25-54-12-000-003):
(a) FOR [3HC] (FWD CARGO DUCT SENSOR)
- 132KW and/or
(4) Remove the duct temperature sensor 3HC (Ref. AMM TASK 21-43-14-000-002).
(5) Remove the duct temperature sensor 4HC (Ref. AMM TASK 21-43-14-000-003).
F. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the Aft cargo-compartment door 826.
(2) Open the Aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel (Ref. AMM TASK 25-55-11-000-003):
(a) FOR [13HC] (AFT CARGO DUCT SENSOR)
(4) Remove the access panel (Ref. AMM TASK 25-55-11-000-002):
(a) FOR [14HC] (AFT CARGO COMP SENSOR)
(5) Remove the duct temperature sensor(s) 13HC and/or 14HC (Ref. AMM TASK 21-43-15-000-001).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the Aft cargo-compartment door 826.
(2) Open the Aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel (Ref. AMM TASK 25-55-11-000-003):
(a) FOR [13HC] (AFT CARGO DUCT SENSOR)
(4) Remove the access panel (Ref. AMM TASK 25-55-11-000-002):
(a) FOR [14HC] (AFT CARGO COMP SENSOR)
(5) Remove the duct temperature sensor(s) 13HC and/or 14HC (Ref. AMM TASK 21-43-15-000-001).
Subtask 21-43-00-100-051-A ** ON A/C NOT FOR ALL
A. Cleaning of the Duct Temperature Sensor
(2) Carefully remove any foreign matter from between the connector pins and from around the thermistor beads using a BRUSH - NON METALLIC, SOFT moistened with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
Subtask 21-43-00-420-050-A ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Remove any moisture, condensation or dust from the duct temperature sensor with a clean dry Textile-Lint free Cotton - (Material No.14SBA1) . (2) Carefully remove any foreign matter from between the connector pins and from around the thermistor beads using a BRUSH - NON METALLIC, SOFT moistened with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
B. Installation of the Duct Temperature Sensor
(2) Install the duct temperature sensor 4HC (Ref. AMM TASK 21-43-14-400-003).
(3) Make sure that the work area is clean and clear of tools and other items.
Subtask 21-43-00-100-051-B ** ON A/C NOT FOR ALL NOTE: Do not install the access panels at this time.
(1) Install the duct temperature sensor 3HC (Ref. AMM TASK 21-43-14-400-002). (2) Install the duct temperature sensor 4HC (Ref. AMM TASK 21-43-14-400-003).
(3) Make sure that the work area is clean and clear of tools and other items.
C. Cleaning of the Duct Temperature Sensor
(2) Carefully remove any foreign matter from the holes in the body of the sensor using a BRUSH - NON METALLIC, SOFT moistened with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
Subtask 21-43-00-420-050-B ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Remove any moisture, condensation or dust from the duct temperature sensor with a clean dry Textile-Lint free Cotton - (Material No.14SBA1) . (2) Carefully remove any foreign matter from the holes in the body of the sensor using a BRUSH - NON METALLIC, SOFT moistened with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
D. Installation of the Duct Temperature Sensor
(2) Make sure that the work area is clean and clear of tools and other items.
Subtask 21-43-00-865-066-A ** ON A/C NOT FOR ALL NOTE: Do not install the access panels at this time.
(1) Install the duct temperature sensor(s) 13HC and/or 14HC (Ref. AMM TASK 21-43-15-400-001). (2) Make sure that the work area is clean and clear of tools and other items.
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-43-00-865-079-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 3HC (FWD CARGO DUCT SENSOR) | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
| FOR FIN: 4HC (FWD CARGO COMP SENSOR) | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
F. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-43-00-865-092-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 13HC (AFT CARGO DUCT SENSOR) | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
| FOR FIN: 14HC (AFT CARGO COMP SENSOR) | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
G. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-43-00-710-060-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
Subtask 21-43-00-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 25-54-12-400-003):
(a) FOR [3HC] (FWD CARGO DUCT SENSOR)
(3) Close the Fwd cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Subtask 21-43-00-410-059-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 25-54-12-400-003):
(a) FOR [3HC] (FWD CARGO DUCT SENSOR)
- 132KW and/or
(3) Close the Fwd cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 25-55-11-400-003):
(a) FOR [13HC] (AFT CARGO DUCT SENSOR)
(3) Install the access panel (Ref. AMM TASK 25-55-11-400-002):
(a) FOR [14HC] (AFT CARGO COMP SENSOR)
(4) Close the Aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002),
(5) Remove the access platform(s).
(6) Remove the WARNING NOTICE(S).
Subtask 21-43-00-862-063-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 25-55-11-400-003):
(a) FOR [13HC] (AFT CARGO DUCT SENSOR)
(3) Install the access panel (Ref. AMM TASK 25-55-11-400-002):
(a) FOR [14HC] (AFT CARGO COMP SENSOR)
(4) Close the Aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002),
(5) Remove the access platform(s).
(6) Remove the WARNING NOTICE(S).