W DOC AIRBUS | AMM A320F

Removal of the Air Outlet Heater


TASK 21-41-51-000-001-A
Removal of the Air Outlet Heater


FIN: 3HE ** ON A/C NOT FOR ALL
FIN: 4HE ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
811
FOR [3HE] (HEATER-AIR OUTLET, L)
211AW, 211BZ
FOR [4HE] (HEATER-AIR OUTLET, R)
212AW, 212BZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-13-41-000-002-A
Removal of the Sidewall Panels
3. Job Set-up
Subtask 21-41-51-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-41-51-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
   (2) Open the access door 811.
Subtask 21-41-51-865-053-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUCKPT/FOOT/HEATERS1HEV23
Subtask 21-41-51-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) In the cockpit, remove the sidewall panels as necessary (Ref. AMM TASK 25-13-41-000-002):
     (a) FOR [3HE] (HEATER-AIR OUTLET, L)
211BZ 211AW
     (b) FOR [4HE] (HEATER-AIR OUTLET, R)
212BZ 212AW
Subtask 21-41-51-941-050-A ** ON A/C NOT FOR ALL
E. Safety Precautions
   (1) On the AIR COND panel 30VU:
     (a) Make sure that:
  • The APU BLEED pushbutton switch is released
  • The ENG 1 BLEED and ENG 2 BLEED pushbutton switches are released
  • The PACK 1 and PACK 2 pushbutton switches are released.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and LP ground connectors, put a WARNING NOTICE(S) in position to tell persons not to supply the ground source.
4. Procedure
Subtask 21-41-51-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Air Outlet Heater
   (1) Disconnect the electrical connector (6).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the clamp (4) and the duct (5) from the air outlet heater (2).
   (4) Remove the four screws (7), washers (8) and nuts (9).
   (5) Remove the clamp (3).
   (6) Remove the air outlet heater (2).
[Rev.10 from 2021] 2026.04.02 06:11:17 UTC