Removal of the Residual Pressure Control Unit
TASK 21-31-35-000-001-A
Removal of the Residual Pressure Control Unit
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-31-35-861-050-A ** ON A/C NOT FOR ALL Subtask 21-31-35-865-050-A ** ON A/C NOT FOR ALL
Subtask 21-31-35-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:15 UTC
Removal of the Residual Pressure Control Unit
FIN: 9HL ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 21-31-35-861-050-A ** ON A/C NOT FOR ALL Subtask 21-31-35-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-31-35-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | RPCU | 4HL | X23 |
C. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 811.
(2) Open the access door 811.
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 811.
(2) Open the access door 811.
Subtask 21-31-35-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Residual Pressure Control-Unit
(1) Disconnect the electrical connectors (8) and (9).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screw (4) and the washer (3), and disconnect the bonding strap (2).
(4) Remove the screws (7) and the washers (6).
(5) Remove the control unit (5) from the mounting (1).
(1) Disconnect the electrical connectors (8) and (9).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screw (4) and the washer (3), and disconnect the bonding strap (2).
(4) Remove the screws (7) and the washers (6).
(5) Remove the control unit (5) from the mounting (1).
Residual Pressure Control Unit