Installation of the Aft Cargo-Compartment Ventilation-Extraction-Fan
TASK 21-28-54-400-001-A
Installation of the Aft Cargo-Compartment Ventilation-Extraction-Fan
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 21-28-54-860-050-A ** ON A/C NOT FOR ALL
Subtask 21-28-54-420-050-A ** ON A/C NOT FOR ALL
Subtask 21-28-54-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:12 UTC
Installation of the Aft Cargo-Compartment Ventilation-Extraction-Fan
FIN: 35HN ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162DW, 826 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 7 | EXTRUDED RUBBER SEAL | AIPC 21-28-04-08-050 |
| 7 | EXTRUDED RUBBER SEAL | AIPC 21-28-84-03-100 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-28-00-720-004-A | Functional Test of the AFT Cargo-Compartment Ventilation-System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| TASK 52-30-00-860-004-A | Close the FWD or Aft Cargo-Compartment Door with the Hand Pump |
Subtask 21-28-54-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position below aft cargo-compartment door 826.
(4) Make sure that CARGO COMPT LIGHT switch 8LU is set to the ON position.
(5) Make sure that access panel 162DW is removed (Ref. AMM TASK 25-55-12-000-001).
Subtask 21-28-54-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position below aft cargo-compartment door 826.
(4) Make sure that CARGO COMPT LIGHT switch 8LU is set to the ON position.
(5) Make sure that access panel 162DW is removed (Ref. AMM TASK 25-55-12-000-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 21-28-54-865-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
Subtask 21-28-54-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Extraction Fan
(1) Remove the blanking plugs from the extraction fan (6), the sleeve (1) and the duct flange (3).
(2) Clean the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Make sure that the extruded rubber seal (7) is in a good condition. If necessary replace the AIPC 21-28-04-08-050 EXTRUDED RUBBER SEAL (7) or AIPC 21-28-84-03-100 EXTRUDED RUBBER SEAL (7).
(5) Put the extruded rubber seal (7), the clamp (8) and the extraction fan (6) in position in the bracket (2).
(8) Put the clamp (4) in position on the extraction fan (6) and the duct flange (3).
(9) TORQUE the clamp (4) to between 0.56 and 0.50 m.daN (49.56 and 44.25 lbf.in )
.
(10) Make sure that the clamp (8) is in the correct position.
(11) TORQUE the clamp (8) to between 0.38 and 0.28 m.daN (33.63 and 24.78 lbf.in )
.
(12) Remove the blanking caps from the disconnected electrical connectors.
(13) Make sure that all the electrical connections are clean and in the correct condition.
(14) Connect the electrical connector (5).
(15) Make sure that the work area is clean and clear of tools and other items.
Subtask 21-28-54-865-062-A ** ON A/C NOT FOR ALL (1) Remove the blanking plugs from the extraction fan (6), the sleeve (1) and the duct flange (3).
(2) Clean the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Make sure that the extruded rubber seal (7) is in a good condition. If necessary replace the AIPC 21-28-04-08-050 EXTRUDED RUBBER SEAL (7) or AIPC 21-28-84-03-100 EXTRUDED RUBBER SEAL (7).
(5) Put the extruded rubber seal (7), the clamp (8) and the extraction fan (6) in position in the bracket (2).
NOTE: Make sure that:
(6) Put the clamp (9) and the sleeve (1) in position on the extraction fan (6). - the arrow on the body of the extraction fan (6) points in the direction of the air flow,
- when you look in the direction of the air flow, the electrical socket on the extraction fan is between the 4 o'clock and the 5 o'clock position,
- the attach device of the clamp (8) is in the 3 o'clock position,
- you do not fully tighten the clamp (8) at this time.
NOTE: The end of the sleeve (1) must be between the coloured markings on the extraction fan (6).
(7) Tighten the clamp (9). (8) Put the clamp (4) in position on the extraction fan (6) and the duct flange (3).
(9) TORQUE the clamp (4) to between 0.56 and 0.50 m.daN (49.56 and 44.25 lbf.in )
. (10) Make sure that the clamp (8) is in the correct position.
(11) TORQUE the clamp (8) to between 0.38 and 0.28 m.daN (33.63 and 24.78 lbf.in )
. (12) Remove the blanking caps from the disconnected electrical connectors.
(13) Make sure that all the electrical connections are clean and in the correct condition.
(14) Connect the electrical connector (5).
(15) Make sure that the work area is clean and clear of tools and other items.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-28-54-720-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
C. Do the functional test of the AFT cargo-compartment ventilation system (Ref. AMM TASK 21-28-00-720-004).
5. Close-upSubtask 21-28-54-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(3) Remove the access platform(s).
(4) Set CARGO COMPT LIGHT switch 8LU to the OFF position.
(5) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002) or (Ref. AMM TASK 52-30-00-860-004).
Subtask 21-28-54-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(3) Remove the access platform(s).
(4) Set CARGO COMPT LIGHT switch 8LU to the OFF position.
(5) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002) or (Ref. AMM TASK 52-30-00-860-004).
Aft Cargo-Compartment Ventilation Extraction-Fan