Removal of the FWD Cargo Compartment Extraction Fan


TASK 21-28-53-000-001-A
Removal of the FWD Cargo Compartment Extraction Fan


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
CAUTION: BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
ZONE: 132
FIN: 6HN ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
132
FORWARD CARGO COMPARTMENT
132KW, 825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-54-12-000-003-A
Removal of the Sidewall Panels in the Forward Cargo Compartment
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 21-28-53-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-28-53-941-051-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) In the cockpit, on the overhead panel, on the AIR COND section of panel 30VU:
     (a) Make sure that:
       1 The APU BLEED pushbutton switch is in the off position (the ON legend is off).
       2 The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
       3 The PACK 1 and PACK 2 pushbutton switches are released (the OFF legends are on).
     (b) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and the LP ground connectors:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
Subtask 21-28-53-865-053-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
122VUFWD CARGO VENT AND HTG/FAN1HNT22
Subtask 21-28-53-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at forward cargo-compartment door 825.
   (2) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
4. Procedure
Subtask 21-28-53-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Extraction Fan
   (1) Disconnect the bonding strip (9).
   (2) Disconnect the electrical connector (10) from the fan (3).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the clamps (5) and (7).
   (5) Move the flexible sleeve (6) on the valve (8) to release the fan (3).
   (6) Remove the clamp (2).
   (7) Hold the fan, open the clamp (4) and remove the fan (3).
   (8) Remove the flexible sleeve (6).
   (9) Put the PLUG-BLANKING in each disconnected line end.