Removal of the FWD Cargo Compartment Extraction Fan
TASK 21-28-53-000-001-A
Removal of the FWD Cargo Compartment Extraction Fan
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-28-53-861-050-A ** ON A/C NOT FOR ALL Subtask 21-28-53-941-051-A ** ON A/C NOT FOR ALL
Subtask 21-28-53-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:12 UTC
Removal of the FWD Cargo Compartment Extraction Fan
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 132 | FORWARD CARGO COMPARTMENT |
| 132KW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-28-53-861-050-A ** ON A/C NOT FOR ALL Subtask 21-28-53-941-051-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) In the cockpit, on the overhead panel, on the AIR COND section of panel 30VU:
(a) Make sure that:
1 The APU BLEED pushbutton switch is in the off position (the ON legend is off).
2 The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
3 The PACK 1 and PACK 2 pushbutton switches are released (the OFF legends are on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
(2) On the HP and the LP ground connectors:
(a) Put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
Subtask 21-28-53-865-053-A ** ON A/C NOT FOR ALL (1) In the cockpit, on the overhead panel, on the AIR COND section of panel 30VU:
(a) Make sure that:
1 The APU BLEED pushbutton switch is in the off position (the ON legend is off).
2 The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
3 The PACK 1 and PACK 2 pushbutton switches are released (the OFF legends are on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
(2) On the HP and the LP ground connectors:
(a) Put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-28-53-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
D. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at forward cargo-compartment door 825.
(2) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at forward cargo-compartment door 825.
(2) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
Subtask 21-28-53-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Extraction Fan
(1) Disconnect the bonding strip (9).
(2) Disconnect the electrical connector (10) from the fan (3).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the clamps (5) and (7).
(5) Move the flexible sleeve (6) on the valve (8) to release the fan (3).
(6) Remove the clamp (2).
(7) Hold the fan, open the clamp (4) and remove the fan (3).
(8) Remove the flexible sleeve (6).
(9) Put the PLUG-BLANKING in each disconnected line end.
(1) Disconnect the bonding strip (9).
(2) Disconnect the electrical connector (10) from the fan (3).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the clamps (5) and (7).
(5) Move the flexible sleeve (6) on the valve (8) to release the fan (3).
(6) Remove the clamp (2).
(7) Hold the fan, open the clamp (4) and remove the fan (3).
(8) Remove the flexible sleeve (6).
(9) Put the PLUG-BLANKING in each disconnected line end.
Extraction Fan