Removal of the Ventilation Controller
TASK 21-28-34-000-001-A
Removal of the Ventilation Controller
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-28-34-861-050-A ** ON A/C NOT FOR ALL Subtask 21-28-34-865-050-A ** ON A/C NOT FOR ALL
Subtask 21-28-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:11 UTC
Removal of the Ventilation Controller
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 126 | LATERAL AVIONIC COMPARTMENT |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 21-28-34-861-050-A ** ON A/C NOT FOR ALL Subtask 21-28-34-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-28-34-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AFT CARGO/VENT & HTG/CTL & MONG | 31HN | C07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/AFT CARGO VENT/FAN | 30HN | S22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the lateral avionics compartment door 822.
(2) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the lateral avionics compartment door 822.
(2) Open the access door 822.
Subtask 21-28-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Ventilation Controller
(1) Disconnect the electrical connector(s) (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the nuts (2).
(4) Remove the ventilation controller (1).
(1) Disconnect the electrical connector(s) (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the nuts (2).
(4) Remove the ventilation controller (1).
Ventilation Controller