W DOC AIRBUS | AMM A320F

Removal of the Ventilation Controller


TASK 21-28-34-000-001-A
Removal of the Ventilation Controller


ZONE: 126
FIN: 10HN ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
126
LATERAL AVIONIC COMPARTMENT
822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
F Ventilation Controller ** ON A/C NOT FOR ALL
F Ventilation Controller ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-28-34-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-28-34-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
** ON A/C NOT FOR ALL
122VUAIR COND/AFT CARGO VENT/FAN30HNS22
** ON A/C NOT FOR ALL
122VUFWD CARGO VENT AND HTG/FAN1HNT22
Subtask 21-28-34-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the lateral avionics compartment door 822.
   (2) Open the access door 822.
4. Procedure
Subtask 21-28-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Ventilation Controller
   (1) Disconnect the electrical connector(s) (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the nuts (2).
   (4) Remove the ventilation controller (1).
[Rev.10 from 2021] 2026.04.02 06:11:11 UTC