Deactivation of the Fwd Cargo-Compartment Ventilation Isolation-Valves
TASK 21-28-00-040-001-A
Deactivation of the Fwd Cargo-Compartment Ventilation Isolation-Valves
MMEL 21-28-02B
FWD CARGO ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-28-00-861-056-A ** ON A/C NOT FOR ALL Subtask 21-28-00-865-057-A ** ON A/C NOT FOR ALL
Subtask 21-28-00-040-052-A ** ON A/C NOT FOR ALL
Subtask 21-28-00-865-096-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:10 UTC
Deactivation of the Fwd Cargo-Compartment Ventilation Isolation-Valves
FIN: 4HN ** ON A/C NOT FOR ALL
FIN: 5HN ** ON A/C NOT FOR ALL
Task Summary
1. Reason for the JobFIN: 5HN ** ON A/C NOT FOR ALL
Task Summary
| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | NO | NO | 0.5 | 0.5 | 1 |
MMEL 21-28-02B
FWD CARGO ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 825 | |
| FOR [4HN] (ISOL VALVE FWD CARGO OUTLET) | |
| 132KW | |
| FOR [5HN] (ISOL VALVE FWD CARGO INLET) | |
| 131QW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-28-00-861-056-A ** ON A/C NOT FOR ALL Subtask 21-28-00-865-057-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-28-00-010-072-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
C. Get Access
(1) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) at the FWD cargo-compartment door 825.
(3) Remove the access panels (Ref. AMM TASK 25-54-12-000-003):
(a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
(b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
4. Procedure(1) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) at the FWD cargo-compartment door 825.
(3) Remove the access panels (Ref. AMM TASK 25-54-12-000-003):
(a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
(b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
Subtask 21-28-00-040-052-A ** ON A/C NOT FOR ALL
A. Deactivation of the FWD Cargo-Compartment Ventilation Isolation Valves
(1) On the isolation valves (2) move the manual override levers (1) to the closed position.
(2) Disconnect the electrical connectors (3), (4HN-A and 5HN-A), and temporarily attach them to the aircraft structure.
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
5. Close-up(1) On the isolation valves (2) move the manual override levers (1) to the closed position.
(2) Disconnect the electrical connectors (3), (4HN-A and 5HN-A), and temporarily attach them to the aircraft structure.
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Subtask 21-28-00-865-096-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 21-28-00-865-097-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-28-00-410-055-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels (Ref. AMM TASK 25-54-12-400-003):
(a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
(b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
(3) Remove the access platform(s).
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Make an entry in the aircraft log book to record the deactivation.
Subtask 21-28-00-862-055-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels (Ref. AMM TASK 25-54-12-400-003):
(a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
(b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
(3) Remove the access platform(s).
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Make an entry in the aircraft log book to record the deactivation.
Cargo-Compartment Ventilation Isolation-Valves - Component Location