Deactivation of the Fwd Cargo-Compartment Ventilation Isolation-Valves


TASK 21-28-00-040-001-A
Deactivation of the Fwd Cargo-Compartment Ventilation Isolation-Valves


FIN: 4HN ** ON A/C NOT FOR ALL
FIN: 5HN ** ON A/C NOT FOR ALL
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESNONO0.50.51
1. Reason for the Job
MMEL 21-28-02B
FWD CARGO ISOLATION VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
132KW
FOR [5HN] (ISOL VALVE FWD CARGO INLET)
131QW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-54-12-000-003-A
Removal of the Sidewall Panels in the Forward Cargo Compartment
TASK 25-54-12-400-003-A
Installation of the Sidewall Panels in the Forward Cargo Compartment
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 21-28-00-861-056-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-28-00-865-057-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
122VUFWD CARGO VENT AND HTG/FAN1HNT22
Subtask 21-28-00-010-072-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) at the FWD cargo-compartment door 825.
   (3) Remove the access panels (Ref. AMM TASK 25-54-12-000-003):
     (a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
     (b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
4. Procedure
Subtask 21-28-00-040-052-A ** ON A/C NOT FOR ALL
A. Deactivation of the FWD Cargo-Compartment Ventilation Isolation Valves
   (1) On the isolation valves (2) move the manual override levers (1) to the closed position.
   (2) Disconnect the electrical connectors (3), (4HN-A and 5HN-A), and temporarily attach them to the aircraft structure.
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
5. Close-up
Subtask 21-28-00-865-096-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUFWD CARGO VENT AND HTG/FAN1HNT22
Subtask 21-28-00-865-097-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FWD CARGO/VENT/CTL & MONG2HNC08
Subtask 21-28-00-410-055-C ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels (Ref. AMM TASK 25-54-12-400-003):
     (a) FOR [4HN] (ISOL VALVE FWD CARGO OUTLET)
     (b) FOR [5HN] (ISOL VALVE FWD CARGO INLET)
   (3) Remove the access platform(s).
   (4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
   (5) Make an entry in the aircraft log book to record the deactivation.
Subtask 21-28-00-862-055-A ** ON A/C NOT FOR ALL
D. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).