Removal of the Air Inlet Check Valve


TASK 21-26-56-000-001-A
Removal of the Air Inlet Check Valve


FIN: 2150HM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-26-43-000-003-A
Removal of the Filter Assembly
TASK 21-26-43-000-006-A
Removal of the Filter Assembly
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
Subtask 21-26-56-861-050-A
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 21-26-56-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 21-26-56-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position below access door 824.
   (2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 21-26-56-020-050-C
A. Removal of the Air Inlet Check-Valve
   (1) Remove the clamp (3).
   (2) Remove the filter assembly (1) (Ref. AMM TASK 21-26-43-000-006) or (Ref. AMM TASK 21-26-43-000-003).
   (3) Remove and discard the O-ring (2).
   (4) Remove the screws (6) and the washers (5).
   (5) Remove the check valve (4).
   (6) Put the PLUG - BLANKING on the disconnected line ends.