W DOC AIRBUS | AMM A320F

Removal of the Avionics-Ventilation Skin Air-Inlet-Valve


TASK 21-26-52-000-001-A
Removal of the Avionics-Ventilation Skin Air-Inlet-Valve


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 127
FIN: 15HQ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
1
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 21-26-52-861-052-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-52-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-52-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position on the left side of the aircraft below the valve.
4. Procedure
Subtask 21-26-52-020-050-A
A. Removal of the Avionics-Ventilation Skin Air-Inlet-Valve
   (1) Remove the six screws (2) and the four screws (3) and then release the valve (4).
   (2) Make a mark on the valve (4) at the location of the four screws (3). This helps you to install it correctly.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (3) Disconnect the electrical connector (6).
   (4) Remove the valve (4) and discard the O-ring (5).
   (5) Remove the sealant from the valve (4) and the structure (1).
   (6) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the remaining sealant from the mating surfaces.
   (7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (8) Put the PLUG - BLANKING on the air inlet.